Specifications

MECHANICAL
01–10–15
01–10
End Of Sie
VALVE SPRING INSPECTION
E5U011012125E01
1. Apply pressing force to the pressure spring and inspect the spring height.
If it is less than the specification, replace the
valve spring.
Valve spring pressing force
390 N {39.76 kgf, 87.67 lbf}
Valve spring standard height H
28.68 mm {1.129 in}
2. Measure the out-of-square of the valve spring,
using a square, as shown in the figure.
(1) Rotate the valve spring one full turn and
measure "A" at the point where the gap is the
largest.
If it exceeds the specification, replace the
valve spring.
Valve spring out-of-square (Maximum)
1.95 mm {0.0767 in}
End Of Sie
CAMSHAFT INSPECTION
E5U011012420E01
1. Set the No.1 and No.5 journals on V-blocks.
2. Measure the camshaft runout.
If it exceeds the specification, replace the
camshaft.
Maximum runout (Maximum)
0.03 mm {0.0012 in}
3. Measure the cam lobe height at the two points as
shown in the figure.
If it is less than the specification, replace the
camshaft.
Camshaft standard height (mm {in})
With variable valve timing mechanism
IN: 42.44 {1.671}
EX: 41.18 {1.621}
Without variable valve timing mechanism
IN: 42.12 {1.659}
EX: 41.08 {1.618}
Camshaft minimum height (mm {in})
With variable valve timing mechanism
IN: 42.33 {1.666}
EX: 41.06 {1.616}
Without variable valve timing mechanism
IN: 42.01 {1.653}
EX: 40.96 {1.612}
ADJ2224E028
A
UPPER
LOWER
B3E0110E073
B3E0110E074
B3E0110E076