Specifications

TROUBLESHOOTING (ABS/TCS/DYNAMIC STABILITY CONTROL)
P103
P
4. Shake each connector or wire harness a bit
vertically and horizontally while monitoring the
PID.
If PID value is unstable, check for poor
connection.
Inspection method for sensors
1. Connect WDS or equivalent to DLC-2.
2. Turn ignition key to ON (Engine OFF).
Note
If engine starts and runs, perform the following steps at idle.
3. Access PIDs for the switch you are inspecting.
4. Vibrate the sensor slightly with your finger.
If PID value is unstable or malfunction occurs, check for poor connection and/or poorly mounted sensor.
Malfunction data monitor method
1. Perform malfunction reappearance test according to malfunction reappearance mode and malfunction data
monitor. The malfunction cause is found in the malfunction data.
Malfunction data monitor using SST (ABS/TCS: 49 G066 001, DSC: 49 G066 004)
Connector terminal check method
1. Check the connection condition of each female terminal.
2. Insert male terminal; fit female terminal size to
female terminal and check to see whether
malfunction is in female terminal or not.
End Of Si e
YDE6980W002
A6E6921W016
Y3E6980W001