5 INSPECT SHIFT SOLENOID C CONNECTOR
FOR POOR CONNECTION
• Disconnect shift solenoid C connector.
• Check for poor connection (damaged/pulled-
out terminals, corrosion, etc.).
• Is connection okay?
Yes Go to next step.
No Repair or replace connector and/or terminal, then go to
Step 11.
6 INSPECT RESISTANCE
• Inspect resistance between shift solenoid C
terminals A and B (part-side).
• Is resistance within 1.04.2 ohms?
(See K27 Resistance Inspection (Off-Vehicle
Inspection).)
Yes Replace solenoid harness, then go to Step 11.
No Verify shift solenoid C installation.
• If solenoid installed correctly, replace solenoid, then go
to Step 11.
(See K28 SOLENOID VALVE REMOVAL/
INSTALLATION.)
7 INSPECT PCM CONNECTOR FOR POOR
CONNECTION
• Disconnect PCM connector.
• Check for poor connection (damaged/pulled-
out terminals, corrosion, etc.).
• Is connection okay?
Yes Go to next step.
No Repair or replace connector and/or terminals, then go to
Step 11.
8 INSPECT ATX CONNECTOR CIRCUIT FOR
OPEN
• inspect for continuity between PCM terminal
4Y (harness-side) and ATX connector terminal
G (vehicle harness-side).
• Is there continuity between terminals?
Yes Go to next step.
No Repair or replace harness, then go to Step 11.
9 INSPECT ATX CONNECTOR CIRCUIT FOR
SHORT TO POWER
• Turn ignition key to ON (engine OFF).
• Check voltage at ATX connector terminal G
(vehicle harness-side).
• Is voltage 0 V?
Yes Go to next step.
No Repair or replace harness, then go to Step 11.
10 INSPECT PCM CIRCUIT FOR SHORT TO
GROUND
• Turn ignition key to OFF.
• Inspect for continuity between PCM terminal
4Y (harness-side) and body ground.
• Is there continuity?
Yes Repair or replace harness, then go to Step 11.
No Go to next step.
11 VERIFY TROUBLESHOOTING OF DTC P0763
COMPLETED
• Make sure to reconnect all disconnected
connectors.
• Clear DTC from memory using WDS or
equivalent.
• Drive vehicle in D range and make sure that
gears shift smoothly from 1GR to 4GR.
• Are any DTCs present?
Yes Replace PCM, then go to next step.
(See F43 PCM REMOVAL/INSTALLATION.)
No No concern is detected. Go to next step.
12 VERIFY AFTER REPAIR PROCEDURE
• Perform After Repair Procedure.
(See K52 AFTER REPAIR PROCEDURE.)
• Are any DTCs present?
Yes Go to applicable DTC inspection.
No Troubleshooting completed.
STEP INSPECTION ACTION