Specifications

ON-BOARD DIAGNOSTIC
K85
K
DTC P0753
A6E567001030W22
DTC P0753 Shift solenoid A malfunction (electrical)
DETECTION
CONDITION
If PCM detects either of following conditions, PCM determines that shift solenoid A circuit has a
malfunction:
Shift solenoid A voltage is stuck at B+ after engine start.
Shift solenoid A voltage is stuck at 0 V after engine start.
Diagnostic support note:
This is a continuous monitor (CCM).
MIL illuminates if PCM detects the above malfunction conditions during first drive cycle.
PENDING CODE is not available.
FREEZE FRAME DATA is available.
HOLD indicator light flashes.
DTC is stored in the PCM memory.
POSSIBLE
CAUSE
Shift solenoid A malfunction
Short to ground between ATX connector terminal A and PCM terminal 4AB
Short to power between ATX connector terminal A and PCM terminal 4AB
Open circuit between shift solenoid A terminal B and ATX connector terminal A
Open circuit between ATX connector terminal A and PCM terminal 4AB
Open circuit between shift solenoid A terminal A and body ground point
Damaged connector between shift solenoid A and PCM
PCM malfunction