Specifications

AUTOMATIC TRANSAXLE
K19
K
6. Loosen the TR switch mounting bolts.
7. Measure the resistance between the terminals B
and C.
8. Adjust the switch to the point as follow.
Resistance standard value
750 ohms
9. Tighten the TR switch mounting bolts.
Tightening torque
811 N·m {82112 kgf·cm, 7197 in·lbf}
10. Move the selector lever to N position.
11. Verify that the TR switch is aligned with N
position.
12. Connect the TR switch connector.
13. Install the clip to the selector cable as shown in
the figure.
14. Connect the selector cable to the manual shaft
lever as shown in the figure.
15. Inspect operation of the TR switch. (See K14
TRANSAXLE RANGE (TR) SWITCH
INSPECTION.)
If not as specified, readjust the TR switch.
16. Install the air cleaner component. (See F10
INTAKE-AIR SYSTEM REMOVAL/
INSTALLATION.)
17. Connect the negative battery cable.
End Of Sie
TRANSAXLE FLUID TEMPERATURE (TFT) SENSOR INSPECTION
A6E561419010W01
On-Vehicle Inspection
1. Disconnect the negative battery cable.
2. Remove the air cleaner component. (See F10 INTAKE-AIR SYSTEM REMOVAL/INSTALLATION.)
Caution
Water or foreign objects entering the connector can cause a poor connection or corrosion. Be
sure not to drop water or foreign objects on the connector when disconnecting it.
A6E5614W020
A6E5614W010
A6E5614W018
A6E5614W019