Specifications

F186
TROUBLESHOOTING
NO.1 MELTING OF MAIN OR OTHER FUSES
A6E398018881W03
End Of Sie
NO.2 MIL ILLUMINATES
A6E398018881W04
1 MELTING OF MAIN OR OTHER FUSES
[TROUBLESHOOTING HINTS]
Inspect condition of fuse.
Damaged fuse Related wiring harness
MAIN IG KEY2 fuse
AD FAN fuse
FAN fuse
ENG +B PCM
IG KEY1 Ignition switch
 ENGINE IG fuse
 METER IG fuse
IG KEY2 Ignition switch
AD FAN Cooling fan relay
 Cooling fan motor
FAN Cooling fan relay (L8-DE, LF-DE (except G.C.C. specs.)
 Cooling fan motor
ENGINE IG Main relay
PCM
Ignition coil
Condenser
METER IG Cooling fan relay
PCM
ENG BAR VSS (ATX)
OCV
VIS solenoid valve
VAD control solenoid valve
Purge solenoid valve
EGR valve
MAF/IAT sensor
ENG BAR2 Heated oxygen sensor heater
INJ PCM
Fuel pump relay
PCM
Fuel injector
FUEL PUMP Fuel pump relay
 Fuel pump
2 MIL ILLUMITATES
DESCRIPTION MIL is illuminated incorrectly.
POSSIBLE CAUSE
PCM illuminates for emission-related concern (DTC is stored in PCM)
Instrument cluster malfunction
Note
If MIL blinks at steady rate, misfire condition could possibly exist.