NO.8 NO COOL AIR
A6E858001038W10
When performing an asterisked (*) troubleshooting inspection, shake the wiring harness and connectors while
performing the inspection to discover whether poor contact points are the cause of any intermittent
malfunctions. If there is a problem, check to make sure connectors, terminals and wiring harnesses are
connected correctly and undamaged.
Diagnostic procedure
8 No cool air
DESCRIPTION Magnetic clutch does not operate.
POSSIBLE
CAUSE
Malfunction in PCM A/C cut control system (Step 3)
Malfunction in climate control unit (Step 4)
Malfunction in refrigerant pressure switch (Steps 5, 79)
Malfunction in PCM (A/C signal) (Step 6)
Malfunction in PCM (IG1 signal) (Steps 10, 11)
Malfunction in A/C compressor (Step 12)
Malfunction in A/C relay (Steps 1315)
Malfunction in evaporator temperature sensor (Step 16)
STEP INSPECTION ACTION
1 INSPECT AIR BLOW OUT
Does air blow out?
Yes Go to next step.
No Go to Step 1 of troubleshooting indexes No.1 and 2.
2 INSPECT A/C COMPRESSOR OPERATION
Start engine.
Turn A/C switch and fan switch on.
Does A/C compressor operate?
Yes Go to Step 1 of troubleshooting index No.7.
No Go to next step.
3 INSPECT FOR DTC IN PCM
Inspect for DTCs related to the PCM on-
board diagnostic system.
Are any DTCs displayed?
Yes Go to appropriate inspection procedure.
No Go to next step.
4 INSPECT TO SEE WHETHER MALFUNCTION
IS IN CLIMATE CONTROL UNIT OR
ELSEWHERE
Does cool air blow out when terminal 1P of
climate control unit connector (24-pin, A/C
signal) is grounded?
Yes Replace climate control unit, then go to Step 17.
No Release short, then go to next step.
5* INSPECT TO SEE WHETHER MALFUNCTION
IS IN A/C SIGNAL CIRCUIT (BETWEEN
REFRIGERANT PRESSURE SWITCH AND
PCM) OR ELSEWHERE
Test voltage at following terminal of
refrigerant pressure switch.
 Terminal B (A/C signal)
Is voltage approximately 12 V?
Yes Go to Step 7.
No Go to next step.
6* INSPECT TO SEE WHETHER MALFUNCTION
(LACK OF CONTINUITY) IS IN WIRING
HARNESS (BETWEEN REFRIGERANT
PRESSURE SWITCH AND PCM) OR PCM
Test voltage at A/C signal terminal of PCM.
Is voltage approximately 12 V?
Yes Repair wiring harness between PCM and refrigerant
pressure switch, then go to Step 17.
No Inspect PCM, then go to Step 17.
7 INSPECT TO SEE WHETHER MALFUNCTION
IS IN REFRIGERANT PRESSURE SWITCH,
REFRIGERANT AMOUNT, OR ELSEWHERE
Does cool air blow out when terminals A and
B of refrigerant pressure switch connector
are shorted?
Yes Go to Step 9.
No Go to next step.
8* INSPECT TO SEE WHETHER MALFUNCTION
IS IN WIRING HARNESS (BETWEEN
REFRIGERANT PRESSURE SWITCH AND
CLIMATE CONTROL UNIT) OR ELSEWHERE
Test voltage at following terminal of climate
control unit.
 Terminal 1P (24-pin, A/C signal)
Is voltage approximately 12 V?
Yes Go to Step 10.
No Repair wiring harness between refrigerant pressure switch
and climate control unit, then go to Step 17.