Specifications

U34
CONTROL SYSTEM
AIRFLOW MODE ACTUATOR INSPECTION
A6E854061070W02
1. Connect battery positive voltage to terminal D or F and ground to terminal F or D of the airflow mode actuator.
2. Verify that the airflow mode actuator operates as shown below.
If not as specified, replace the airflow mode actuator.
3. Verify that the resistance between the terminals
of the airflow mode actuator is as shown in the
graph.
If not as specified, replace the airflow mode
actuator.
End Of Sie
Connection
Movement
B+ GND
D F DEFROSTER VENT
F D VENT DEFROSTER
A6E8540W008
A6E8540W009
A6E8540W046
A6E8540W047