Specifications

INTAKE-AIR SYSTEM
F13
F
VARIABLE AIR DUCT (VAD) CONTROL SOLENOID VALVE INSPECTION (L3)
A6E391013000W03
1. Remove the VAD control solenoid valve. (See F10 INTAKE-AIR SYSTEM REMOVAL/INSTALLATION.)
2. Inspect airflow between the ports under the
following conditions.
If not as specified, replace the VAD control
solenoid valve.
If as specified, carry out the Circuit Open/
Short Inspection.
Circuit Open/Short Inspection
1. Disconnect the PCM connector. (See F43 PCM REMOVAL/INSTALLATION.)
2. Inspect the following wiring harness for open or
short (continuity check).
Open circuit
If there is no continuity, the circuit is open. Repair
or replace the harness.
VAD control solenoid valve terminal B
(harness-side) and PCM terminal 4C
VAD control solenoid valve terminal A
(harness-side) and main relay terminal C
(harness-side)
Short circuit
If there is continuity, the circuit is shorted. Repair
or replace the harness.
VAD control solenoid valve terminal B
(harness-side) and body GND
VAD control solenoid valve terminal A (harness-side) and power supply
End Of Sie
VARIABLE AIR DUCT (VAD) CHECK VALVE (ONE-WAY) INSPECTION (L3)
A6E391013000W04
1. Remove the VAD check valve (one-way). (See F10 INTAKE-AIR SYSTEM REMOVAL/INSTALLATION
2. Blow through A and verify that air flows from B.
3. Blow through B and verify that air does not flow from A.
If not as specified, replace the VAD check valve (one-way).
End Of Sie
IDLE AIR CONTROL (IAC) VALVE INSPECTION
A6E391020661W01
Note
Perform the following inspection only when directed.
Operation Test
1. Carry out the Idle Air Control Inspection. (See F229 Idle Air Control System Inspection.)
If not as specified, perform the further inspection for the IAC valve.
Resistance Inspection
1. Disconnect the negative battery cable.
A6E3910W036
A6E3910W037
A6E3910W038
A6E3910W039