Specifications
T162
ON-BOARD DIAGNOSTIC [IMMOBILIZER SYSTEM]
End Of Sie
DTC B2103
A6E817067000W04
Diagnostic procedure
End Of Sie
6 INSPECT COIL OUTPUT SIGNAL CIRCUIT
• Connect coil and PCM connectors.
• Turn ignition switch to ON position.
• Measure voltage at terminal A of coil
connector.
• Is voltage more than 9 V?
Yes Go to Step 10.
No Go to next step.
7 INSPECT COIL OUTPUT SIGNAL CIRCUIT
• Turn ignition switch to OFF position.
• Disconnect PCM connector.
• Measure resistance between PCM connector
terminal 2Q and ground.
• Is resistance more than 10 kilohms?
Yes Go to Step 9.
No Go to next step.
8 INSPECT COIL OUTPUT SIGNAL CIRCUIT
FOR SHORT TO GND
• Disconnect coil connector.
• Measure resistance between coil connector
terminal A and ground.
• Is resistance more than 10 kilohms?
Yes Replace coil.
(See T90 COIL REMOVAL/INSTALLATION)
No Repair wiring harness.
9 INSPECT COMMUNICATION CIRCUIT
(OUTPUT) FOR CONTINUITY
• Disconnect coil and PCM connectors.
• Is there continuity between coil connector
terminal A and PCM terminal 2Q?
Yes Replace PCM and reprogram immobilizer system.
(See T90 IMMOBILIZER SYSTEM REPROGRAM
PROCEDURE)
No Repair wirimg harness.
10 INSPECT COMMUNICATION CIRCUIT
(OUTPUT) FOR CONTINUITY
• Disconnect coil and PCM connectors.
• Is there continuity between coil connector
terminal A and PCM terminal 2Q?
Yes Replace coil.
(See T90 COIL REMOVAL/INSTALLATION)
No Go to next step.
11 INSPECT COIL OUTPUT CIRCUIT FOR
SHORT TO POWER SUPPLY
• Disconnect coil connector.
• Measure voltage at terminal A of coil
connector.
• Is there voltage?
Yes Repair wirimg harness.
No Replace PCM and reprogram immobilizer system.
(See T90 IMMOBILIZER SYSTEM REPROGRAM
PROCEDURE)
12 INSPECT PCM
• Turn ignition switch from LOCK position to
START position for 2 seconds.
• Does security light indicate DTC B1681
again?
Yes Replace PCM and reprogram immobilizer system.
(See T90 IMMOBILIZER SYSTEM REPROGRAM
PROCEDURE)
No Troubleshooting is completed.
STEP INSPECTION ACTION
DTC B2103 Coil not connected.
POSSIBLE
CAUSE
• Defective Coil
• Poor connection of coil connector
STEP INSPECTION ACTION
INSPECT CONNECTOR CONNECTION
• Is connector of coil and PCM connected
securely?
Yes Replace coil.
(See T90 COIL REMOVAL/INSTALLATION)
No Connect connector securely.