Installation Instructions
Table Of Contents
- Table of Contents
- Table des matières
- Range Hood Safety
- installation requirements
- Installation Instructions
- Prepare Location
- Prepare In-Line Smart Kit
- Install In-Line Smart Kit KVWB40DS Series Range Hoods
- Complete Installation
- Make Electrical Connection
- Install In-Line Smart Kit KVUB60DS Series Range Hoods
- Complete Installation
- Make Electrical Connection
- Install In-Line Smart Kit JXW85DS, JXI85DS, KVWB60DS, and KVIB60DS Series Range Hoods
- Complete Installation
- Make Electrical Connection
- Install In-Line Smart Kit WVW75UC and WV175UC Series Range Hoods
- Complete Installation
- Make Electrical Connection
- wiring diagram
- sÉcuritÉ de la hotte de cuisiniÈre
- Exigences d’installation
- Instructions d’installation
- Préparation de l’emplacement
- Préparation du ventilateur déporté intelligent
- Installation du ventilateur déporté intelligent Hottes série KVWB40DS
- Achever l’installation
- Raccordement électrique
- Installation du ventilateur déporté intelligent Hottes série KVUB60DS
- Achever l’installation
- Raccordement électrique
- Installation du ventilateur déporté intelligent Hottes série JXW85DS, JXI85DS, KVWB60DS et KVIB60DS
- Achever l’installation
- Raccordement électrique
- Installation du ventilateur déporté intelligent Hottes série WVW75UC et WV175UC
- Achever l’installation
- Raccordement électrique
- schÉma de cÂblage
7
Install In-Line Smart Kit
KVWB40DS Series Range Hoods
Remove Blower Motor from Range Hood Housing
1. Disconnect power.
2. Using two or more people, place the range hood on its back.
Be sure to set the range hood on a covered surface.
3. Using the T10 Torx
®
adapter, remove the 8 screws securing
the bottom panel to the range hood. Remove the bottom
panel and set it aside.
4. Using the T10 Torx
®
adapter, remove the 4 screws from the
blower motor cover plate. Remove the cover plate from the
motor and set it aside.
5.
Disconnect the blower motor from the range hood wiring. Press
the top and bottom clip of the 9-pin electrical connector to
disconnect.
6. Using the T20
®
Torx
®
adapter with a long extension, remove
the 6 screws that secure the blower motor and insulation
retainers (2) to the range hood housing. Set the screws and
insulating retainers aside.
A. Bottom panel
B. Screws (8)
C. Range hood
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
WARNING
Excessive Weight Hazard
Use two or more people to move and install
range hood.
Failure to do so can result in back or other injury.
C
B
A
A. Blower motor cover plate
B. Screws (4)
C. Range hood
A. Blower motor
B. Screws - insulation retainer (2)
C. Insulation retainers (2)
D. Screws - blower motor mounting (4)
A
C
B
A
B
C
D
D