FURNACE
MODELS
(BTU)
FURNACE
INSTALLATION
SINGLE PIPE LENGTH (FT.)
with 1 long radius elbow**
DIRECT VENT,
DUAL PIPE LENGTH (ft.) WITH
1 long radius elbow on each pipe**
OUTLET OUTLET INLET/OUTLET INLET/OUTLET
2” Diameter 3” Diameter 2” Diameter 3” Diameter
60,000
Upflow 90 90 90 90
Horizontal 50 90 50 90
Downflow 30 90 30 90
80,000
Upflow 40 90 40 90
Horizontal 30 90 30 90
Downflow 30 90 30 90
100,000
Upflow 30 90 30 90
Horizontal 30 90 30 90
Downflow 30 90 25 90
120,000
Upflow N/A 90 N/A 90
Horizontal N/A 90 N/A 90
Downflow N/A 90 N/A 90
*NOTES:
1. Subtract 2.5 ft. for each additional 2 inch long radius elbow, 5 ft. for each additional 2 inch short radius elbow, 3.5 ft. for each additional 3 inch
long radius elbow, and 7 ft. for each additional 3 inch short radius elbow. Subtract 5ft for each 2” tee and 8ft for each 3” tee.
2. Two 45 degree elbows are equivalent to one 90 degree elbow.
3. This table applies for elevations from sea level to 2,000 ft. For higher elevations, decrease pipe lengths by 8% per 1,000 ft of altitude.
Printed in U.S.A. (05/14)
ACCESSORIES
All models are approved for vertical non direct (1 pipe) and direct (2 pipe) venting applications. See Vent Table below for
specified sizes and allowable lengths.
VENTING
PGC2T (C, L) KITS
Description SKU
Fixed speed -to- variable speed 904880
2" Concentric vent kit 904177
3" Concentric vent kit 904176
"A" Cabinet downflow sub base kit 902974
"B", "C", "D" Cabinet downflow sub base kit 904911
2" Side wall vent kit 904617
3" Side wall vent kit 904347
U.S. LP Conversion kit (0 to 10,000 ft.) 904914
Canada LP Conversion kit (0 to 4,500 ft.) 904915
Bottom return filter 20 per box, "A" cabinet 903088
Bottom return filter 20 per box, "B" cabinet 904916
Bottom return filter 20 per box, "C" cabinet 904917
Bottom return filter 20 per box, "D" cabinet 904918
Side return filter kit 541036
Neutralizer kit 902377