Technical Literature
6
SPECIFICATIONS
PGC2MQ MODEL
NUMBERS: 060DVB 080DVC 100DVC 120DVD
Input - Btuh (a) 60,000 / 30,000 80,000 / 40,000 100,000 / 50,000 120,000 / 60,000
Heating Capacity - Btuh 58,200 / 29,100 77,600 / 38,800 97,000 / 48,500 116,400 / 58,200
AFUE 97.0 97.2 97.4 97.0
Blower D x W 11 x 8 11 x 10 11 x 10 11 x 10
Motor H.P. - Speed - Type 1/2 - Variable 3/4 - Variable 3/4 - Variable 1 - Variable
Motor FLA 6.2 8.7 8.7 11.70
Rated Ext. SP - In. W.C. 0.5 0.5 0.5 0.5
Temperature Rise Range - ºF 30-60 35-65 35-65 40-70
Shipping Weights 130lbs 140lbs 150lbs 165lbs
NOTE: All models are 115V, 60 Hz. Gas Connections are 1/2" N.P.T. AFUE = Annual Fuel Utilization Efficiency
(a) Ratings to 2,000 ft. Over 2,000 ft. reduce 4% for each 1,000 ft. above sea level.
AIRFLOW DATA
Gas Input
Rate
(Btuh)
Target CFM for Selected Circulating Air
Temperature Rises, F
45 50 55 60
Constant
Full
Input
Minimum
Input
Full
Input
Minimum
Input
Full
Input
Minimum
Input
Full
Input
Minimum
Input
60,000 1,110 635 1,000 560 940 515 850 470 950
80,000 1,480 850 1,345 740 1,255 685 1,140 625 1,300
100,000 1,850 1,050 1,680 925 1,565 855 1,460 780 1,760
120,000 2,225 1,270 2,020 1,115 1,890 1,025 1,730 940 2,100
NOTE: This table lists the High and Low target CFMs for each maximum input rate and temperature rise. If the
target CFM is more that 1,600 CFM, it is recommended that two return air openings into the furnace be used.
NOTE: The blower operating range is .1” to .8” ESP in wc.
Description Sku
iQ Controller kit 920620*
* Revision Letter
iQ CONTROLLER KIT