Specifications
©2003 Maytag Appliances Company 16022808 Rev. 0 31
To avoid risk of electrical shock, personal injury or
death; disconnect power to unit before servicing.
Disassembly Procedures
WARNING
!
6. Disconnect the remaining harness connectors.
7. Remove two T –15 Torx screws, attaching Control
Board to Console.
8. Slide Control Board up and to the left to disengage
tabs locking the right side in place.
9. Main Wiring Harness Separates at plug, allowing
Console to be completely removed.