MAYTAG Whole Home Water Filtration System Owner’s Manual Models: MWF4100AWS MWF4200AWS MWF4300AWS Your Operation and Maintenance Guide Table of Contents Dealer and System Information .................................................................. 2 IMPORTANT! READ THIS FIRST ........................................ 3 Safety Instructions....................................................................................... 3 Certifications and Testing.....................................................
Thank you… By purchasing the MAYTAG Whole Home Water Filtration System you have taken the first step in providing safer, great tasting water for the entire home. The MAYTAG Whole Home Water Filtration System is an advanced Point of Entry (POE) water filtration system that uses ultrafilter membrane technology to provide a physical barrier to bacteria, parasites, viruses and particles. The System requires minimal maintenance and will provide you with years of cleaner, safer, better tasting water.
IMPORTANT! READ THIS FIRST • • • • • • • Read this manual carefully prior to use. Permanently locate the manual near the water filtration system. Periodic checks of the MAYTAG Whole Home Water Filtration System are required to ensure safe and efficient operation. Annual maintenance by a MAYTAG Services Qualified Service Technician is required to validate the limited warranty. Cost of annual maintenance is the Owner’s responsibility.
Operational Safety • The MAYTAG Whole Home Water Filtration System is under pressure during use and precautions must be taken. • This device is designed to operate on a 120VAC/15 Amp/ 60Hz line. Do not modify the plug on the power cord. If the plug does not fit the electrical outlet, have a proper outlet installed by a qualified electrician. • To avoid System damage: Ensure that a Stainless Steel Prefilter or Carbon Prefilter is in place during operation of the System.
The MAYTAG Whole Home Water Filtration System must be kept wet at all times after installation. Failure to do so may cause System to dry and become damaged, which may lead to personal injury, and/or physical damage and will void any warranty. Winter Storage • The MAYTAG Whole Home Water Filtration System will be damaged if frozen. The System must be winterized according to the Winterization Procedure by a MAYTAG Services Qualified Service Technician.
Bypassing the MAYTAG Whole Home Water Filtration System will result in unfiltered water entering the household distribution system. This water may be biologically unsafe and drinking this water could result in illness or death. Exercise caution in bypassing the System. Do not drink water from the System while the System is in bypass mode.
Bypass Procedure 1. Close the Inlet and Outlet ball valves (turn handles clockwise). Ball valves are in the closed position when the handle is positioned perpendicular to the water pipe. (See Photo 2a and 2b on previous page.) 2. Open Bypass Valve (turn handle counter-clockwise). 3. Unplug controller. 4.
Model MWF4100AWS: System Tested and Certified by NSF International against NSF/ANSI 42 and 53 for: •Cyst Reduction •Turbidity Reduction •Particulate Reduction - Class 1 •Chlorine, Taste and Odour Reduction Chlorine Reduction Capacity Rating: 396,000/105,000 (litres/gallons) Do not use the MWF4100AWS, with activated carbon filter option, with water that is microbiologically unsafe or of unknown quality unless adequate disinfection before or after the System.
Independent Laboratory Testing Results – Biovir Laboratories The following information is a summary of the MAYTAG Whole Home Water Filtration System and MAYTAG Whole Home Water Filtration System with Activated Carbon Prefilter Independent Laboratory Testing results. Independently Tested By BioVir Laboratories, Inc. , Benicia, California The MAYTAG Whole Home Water Filtration System has been independently tested by BioVir Laboratories, a California Department of Health (CDH) Approved Laboratory.
All MAYTAG Whole Home Water Filtration Products must be installed in accordance with all local building and plumbing codes. The MAYTAG Whole Home Water Filtration System must be protected against freezing and less than 0°C (32 F) temperatures. Failure to do so may cause System to become damaged, which may lead to personal injury and/or physical damage. The MAYTAG Whole Home Water Filtration System must be installed on cold-water distribution systems only.
System Description Figure 1. MAYTAG Whole Home Water Filtration System, components and dimensions AIR VENT CAP 188cm (74”) MINIMUM CLEARANCE REQUIRED PREFILTER HOUSING INLET ¾” FNPT 163cm (64”) MEMBRANE MODULE 119cm (46.75”) DRAIN ¾” FNPT LOCK RING OUTLET ¾” FNPT 64cm (25.
67500006 67500011 Advanced Controller with batteries (2AA) Cap 67500012 Lockring 67500013 Backpulse Tank √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ (Inlet may also require solenoid NO) √ √ √ √ √ √ (Inlet may also require solenoid NO) √ √ 67500014 Base 67500015 Inlet or Outlet Pipe Assembly 67500016 Drain Pipe Assembly 67500017 67500018 Installation Sub Assembly Kit (inlet, outlet, drain, air vent) Solenoid Valve NC (Normally Closed) 67500019 Solenoid Valve NO (Normally Open) 67500020 Hex
MAYTAG Whole Home Water Filtration System and to ensure the limited warranty protection remains in effect. Table 2 outlines the maintenance schedule that should be followed for each Model of the MAYTAG Whole Home Water Filtration System: Table 2 – MAYTAG Whole Home Water Filtration System Maintenance Schedule Model MWF 4200 AWS Model MWF 4100 AWS Required service Part No. Comments Every 12 Mo.
Model MWF 4300 AWS Required service Part No. Comments Every 6 mo. Every 12 Mo. Stainless Steel Prefilter 67500002 Water sources with high levels of particulate will require more frequent cleaning. System cleaning -- Clean Integrity testing* -- Test System 67500007 Backpulse Tank air pressure 67500013 Adjust air pressure as required** External Pre-filter cartridge 67500004 Highly variable service rate, due to variability in raw water quality.
Replacing/Cleaning the Internal Prefilter and Cleaning the System All service and maintenance is to be performed by a MAYTAG Services Qualified Service Technician. Handle End These instructions describe the procedure for installing, replacing or cleaning the MAYTAG Whole Home Water Filtration System internal prefilter and cleaning of the System. Model MWF4100AWS is equipped with the Carbon Prefilter (Photo 3a) and Models MWF4200AWS and MWF4300AWS are equipped with the Stainless Steel Prefilter (Photo 3b).
To reduce the risk of severe injury, illness, death, and/or property damage, read and follow all instructions. Use only Maytag Whole Home Water Filtration System authorized parts where required to repair and service the Maytag Whole Home Water Filtration System. All service and maintenance is to be performed by a MAYTAG Services Qualified Service Technician. Save enough water for cleaning the Stainless Steel Prefilter prior to beginning this procedure.
Remove the cap and internal prefilter from the System 5. After allowing the System to drain for 1 minute, remove the System cap using the cap wrench (not supplied, available from MAYTAG). To remove, turn counter-clockwise as indicated on the top of the cap. Photo 4. Cap Removal 6. Pull the internal prefilter straight up and out of the internal prefilter housing. The prefilter may be a Carbon Prefilter or a Stainless Steel Prefilter depending on your model.
Cleaning System using: • Chlorine bleach (surface and municipal water) • MAYTAG MC1 Cleaning Solution (ground water) This procedure is to be conducted after the internal prefilter has been removed from the System. Do not permit the Carbon Prefilter to come into contact with chlorine bleach or any other form of chlorine. During this procedure the water level in the System should be half way up the internal prefilter cavity.
13. Replace System Cap. Use Cap Wrench to tighten. Ensure that the cap is properly tightened and that the o-ring is clean and intact otherwise leaks may occur. Leaks may result in personal injury or property damage. Fill and Flush for 30 min. 14. Partially open inlet ball valve slowly and watch for leaks. Water will begin to enter and pressurize the System. The air vent mounted on the cap is designed to allow air to enter and exit the System.
To reduce the risk of severe injury, illness, death, and/or property damage, read and follow all instructions. Use only MAYTAG Whole Home Water Filtration System authorized parts where required to repair and service the MAYTAG Whole Home Water Filtration System. Save enough water for cleaning the External Prefilter Housing prior to beginning this procedure. Shut off water 1. Close inlet ball valve (refer to Inlet valve as indicated in Photo 1 on page 6) and/or switch ‘off’ pump upstream of the filter.
Disassemble External Prefilter Housing 5. Using the optional External Prefilter Housing Wrench (available from MAYTAG), turn the housing to the left (counter clockwise) to disassemble (Photo 6). Photo 6. Disassembling the External Prefilter Housing 6. Remove the External Prefilter Cartridge from the External Prefilter Housing. 7. The surface of the External Prefilter Housing may be cleaned with a brush and rinsed with water to remove grit and debris. Discard used External Prefilter Cartridge. 8.
11. Restart pump or slowly open the inlet ball valve. Water will begin to enter and repressurize the System. 12. Press and hold the red button on the External Prefilter head to allow air to exit the External Prefilter Housing during filling. Note: Step 12 is important for the External Prefilter to function properly. 13. If the System is equipped with bypass, ensure that the bypass valve is closed. 14.
Advanced Controller (Model MWF4300AWS) Advanced Controller setup procedure 1. Modes: Use ‘next’ button to toggle through modes. Advanced Controller • • Use with waters having turbidity up to 5.0NTU, Has two output terminals and controls the automated drain and inlet valve. 2. Manual flush: Press ‘next’ until ‘manual’ is flashing. Press ’manual flush’ and hold. If held for longer than 10 seconds, drain valve remains open. Toggle drain valve closed by pressing ‘manual flush’ once. 3.
Advanced Controller Program Program 1 Recommended household occupancy (persons) Up to 4 (Raw) Source water turbidity (NTU) Daily household water consumption No. Flushes per cycle Program 2 Up to 6 <0.5 Peaks to 1.0NTU, <5% of time Program 3 Up to 4 Program 4 Up to 6 <1.0 Peaks to 5.0NTU, <5% of time <5.0 Peaks to 10.0NTU, <5% of time 2 No. System drains per cycle -- Flush water used per day (flow at 7USGAL/min) 14Usgal/d (53L/d) <0.
Never ever use any AUTOMOTIVE type antifreezes when winterizing drinking systems. This may result in serious injury or death. The use of cheaper ‘non-propylene glycol based’ plumbing or RV antifreezes may damage the System’s internal components voiding all warranties. Antifreeze used must be plumbing antifreeze, rated for –50 oC (-58 F), consisting primarily of propylene glycol and must not contain any ethanol or alcohols.
Figure 2 Drain line components for all models. System Drain line Figure 3 Inlet and outlet line components for MWF4100AWS and MWF4200AWS.
Figure 4 Inlet line components for MWF4300AWS. Figure 5 Outlet line components for MWF4300AWS. Before Winter Freeze-up: 1. Close the inlet ball valve. If a bypass valve is installed, the bypass valve must remain closed. 2. Completely drain the System and household piping.
Replacement/Cleaning and System Cleaning Procedure” use the System controller and flush to drain for 5 minutes. To begin draining the household pipes, turn on a nearby cold water tap and leave it on until the tap only drips. Turn off the tap. 3. Remove the drain line from the drain valve and insert a ¾” MNPT Hex PVC plug (available at most hardware stores) to prevent preservative from leaking. Remove hose clamp on drain line and remove elbow.
Prefilter, clean and set aside the Stainless Steel Prefilter. 9. Fill the System with approximately 16 litres (4 US gallons) of –50 oC (-58 F) propylene glycol based plumbing antifreeze to 2” below the top of the prefilter cavity. 10. Unplug the outlet line on the System side to “open the outlet” by removing the ¾” PVC plug. Remove approximately 4 litres (1 US gallon) from the System into an empty propylene glycol based container. The fluid in the System must be 2” above the bottom of the prefilter cavity.
6. Open the outlet ball valve. Open the closest cold water high demand tap (ie. bathtub faucet) for 30 minutes. 7. Open all cold taps one at a time for 1 minute. Flush all toilets once. 8. Close the inlet ball valve. Partially drain System using the flush function for 1 minute to depressurize the System, refer to “Replacing/Cleaning the Internal Prefilter and Cleaning the System” use the System controller in step 4. 9. Remove System Cap using the Cap Wrench. 10.
17. Flush to drain for 5 minutes using the controller (refer to step 8 above). Open the outlet ball valve. Open a nearby cold water high demand tap for 30 minutes. Note: The water may taste slightly different for the first few days but will not be harmful if procedures are followed. It is recommended that first thing in the morning for the first two days after this procedure is complete, leave a cold water tap on full for 30 minutes.
Annual Maintenance Checklist √ Required annually Integrity test Chlorine (or MAYTAG MC1) cleaning Test and record inlet minus outlet pressure and flow rate during test (TMP test) Test backpulse tank air pressure Change internal Activated Carbon filter (MWF4100AWS) or clean internal Stainless Steel filter (MWF4200AWS, MWF4300AWS) Change External sediment prefilter cartridge (MWF4300AWS) Record water meter reading Replace/ check controller batteries Check timer clock setting, flush time setting, program choi
Does the System require electricity? Filtration is accomplished with existing water pressure and no electricity is required to filter your water. Unless required for pump operation, the System will continue to filter water during a power failure. Electrical power is required to operate the automated drain and inlet (solenoid) valves that initiate automatic flushing of the System. If electrical power is not available the System will not conduct automatic flushing.
controller is plugged in) and household pressure will be restored. It is recommended that you also turn each tap on for 10 minutes to flush out stagnant water before use. How do I bypass the MAYTAG Whole Home Water Filtration System? Bypassing the MAYTAG Whole Home Water Filtration System is not recommended unless there is an Emergency and your MAYTAG Whole Home Water Filtration System is not working properly. Contaminated water may enter your home, which can cause serious health problems, even death.
How long does the Carbon Prefilter last? The Activated Carbon Prefilters are designed to filter over 100,000 US gallons (378,000 L). The average homeowner will find it necessary to change the activated carbon filter every 9-12 months. The quality of water, amount of chlorine, other contaminants in the water (chlorine), and the amount of water used determines the actual life of an activated carbon filter.
My lake water is quite dirty and the External Prefilter Cartridge requires replacement quite often. Can I increase the time between replacements of the External Prefilter Cartridge? Yes. In some cases two External Prefilters have been installed. With two External Prefilters, the time to replace the External Prefilter Cartridge is extended by more than twice the original time.
Troubleshooting The following section will help diagnose some of the problems that might occur with the MAYTAG Whole Home Water Filtration System. This guide is provided for information purposes only. Call your MAYTAG Customer Care for assistance if there are any concerns with the MAYTAG Whole Home Water Filtration System. Section of System Problem/Situation Correction/Action General A part is missing.
Section of System Base Controller Advanced Controller Problem/Situation Correction/Action Water is leaking from the bottom. Close the stopcock. Drain does not function. Repeatedly push “Next” until the MANUAL indicator flashes. Press and hold the “manual flush” button for 10 seconds. The “Manual” indicator will appear on the screen. This will open the drain valve for 5 minutes. To toggle the valve closed at any time press the “manual flush” button once.
MAYTAG Whole Home Water Filtration System Operational Specifications Table 6 indicates the operational limitations of the MAYTAG Whole Home Water Filtration System. Table 6 – Operational Limits of the System Recommended Max Flow Rate Per/min (LPM/USgpm) MWF4100AWS …………………………………………………. MWF4200AWS MWF 4300AWS………………………………… 17/4.5 34/9 Pressure Drop at 34 LPM (kPa/psi)* MWF4100AWS ………………………………………………… MWF 4200AWS MWF4300AWS ……………………………… 17/2.
MAYTAG WHOLE HOME WATER FILTRATION SYSTEM Limited Warranty You have just purchased one of the leading whole home water treatment systems available. As an expression of our confidence in Maytag Whole Home Water Filtration System, your drinking water system is warranted to the original end user against defects in material and workmanship when: • • It has been installed in accordance with Maytag specifications by a Maytag Services Qualified Service Installer.
to Systems that have been subject to improper, abnormal or insufficient care or cleaning, or to modification, tampering, alteration, improper service, repair, assembly or disassembly by anyone other than a Maytag Services Qualified Service Technician. to damage or defects resulting from exposure to excessive heat or cold (including extremely hot or cold water), or use on improper electrical current or voltage.
The MAYTAG Whole Home Water Filtration System must be; • kept wet at all times after installation. • winterized prior to temperatures falling below 0°C (32 F). • tested annually using the integrity test. • operated with a prefilter. Failure to do so may cause System to dry and become damaged, which may lead to personal injury, and/or physical damage and will void any warranty.