Technical information

Component Testing Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to washer before servicing, unless
testing requires power.
16022843 Rev 0 December 2003
8
Washer
diagnostic
Program
No user program
should be in progress.
The lid should be
closed and the washer
tub should be empty
before running this test.
Enter operator mode
using service switch.
Push the delicates and
knits program keypad for
more than one second.
If any segments of
display are not working,
replace the control
board.
Push the woolens
program keypad to start
the diagnostic program.
Does cold water run
when an "C" is in the
display?
Push the woolens
program keypad to stop /
start the diagnostics in the
current phase.
Does hot water run
when an "C" is in the
display?
The hoses may be
crossed or the water
valve miswired.
If washer will not fill,
agitate or spin, unplug
washer and check for
continuity of lid switch.
Does switch check
closed with lid closed?
Adjust lid switch or
replace switch if
necessary.
Does hot water run
when an "H" is in the
display?
Push the woolens
program keypad to stop /
start the diagnostics in the
current phase.
Check water shutoff
valves, filter screens
and hose routing.
Yes
No
No
No
Yes
No
Yes
Yes