Technical information

Troubleshooting Procedures
!
WARNING
To avoid risk of electrical shock, personal injury or death; disconnect power to washer before servicing, unless
testing requires power.
June 2006 16027174
©2006 Maytag Services RPL 16023431
5
#
IN
Test or Display
Press LED to
Start
Press LED to
Cancel
Fast
Time-
Down /
Advance
to Next
Step
Press Spin to
start test. Press
Start/Pause
during cycle to
advance.
Press Spin
Quick
Service
Cycle
Press
Temperature
and Soil Level
Press Power
Off (also exits
Service Mode)
Hold Quick
Service Cycle
Step
Press Delay
Start and
Chime together
Press Delay
Start and
Chime to
resume
LED/Switch
Test
Press Delay
Start (then
individual
buttons to test)
Rotate Cycle
Selector
clockwise, the
LED’s around it
will be toggled.
Rotate counter
clockwise, the
7-segment
LED’s toggle.
Press
Start/Pause
button inside
the “Rotary
Cycle Selector,
all of the LED’s
around the
Rotary Cycle
Selector will be
toggled.
Press Power
Off twice after
starting test
Board
Input
Test
Press
Temperature
Press
Temperature
Board
Output
Test /
System Check
Press
Temperature
and Extra
Rinse
Press
Temperature
and Extra
Rinse
Diagnostic
Code Display
(Initial)
Press Chime
1
st
code
displays
Press Chime
again
Test or Display
Press LED to
Start
Press LED to
Cancel
All Diagnostic
Codes
Rotate Cycle
Selector either
direction
N/A
Cycle Count
No. for
Diagnostic
Code
Press and hold
Start/Pause in
center of cycle
selector knob,
while diagnostic
code is
displayed
Release
Start/Pause
(returns to
diagnostic code
display)
Clear All
Diagnostic
Codes
Press Delay
Start + Soil
Level together
while displaying
diagnostic
codes
Display
Software
Version
Press Soil
Level. Press 2
times for
displays with
only 2 character
positions.
Press Soil
Level a 3
rd
time
Cycle Count
Press Extra
Rinse
Quick Spin Test
While in Service Mode, press Delay Start and
Temperature keys to start a Quick Spin Test.
Quick Spin test steps are as follows:
1) Lock the door.
2) Spin clockwise and stop.
3) Spin counterclockwise and stop.
4) Spin counterclockwise, start Drain Pump and spin
to maximum RPM. Hold for 25 seconds.
5) Coast down, stop and turn ‘OFF’ Drain Pump.
6) Unlock Door after 60 seconds. Beeps once.
Hold Quick Spin Step
If the Start Pause key is pressed during the
Quick Spin test, the machine will hold at the
current speed for up to 10 minutes. At the end
of 10 minutes, the machine will resume and
finish the Quick Spin test. To cancel the Hold
and allow the Spin Test to continue, press the