Installation guide

CustomerSe_ic_ _'__
240 EGwardsStreet, SE
Cleveland,Tennessee3731;
Tel: :t23-472-3333
Fax:_23-478-67t0
Turn on gas supply and open the shutoff at the gas valve. Check all gas connections for leaks
using a soap solution. If bubbles occur, tighten connections and recheck. DO NOT use an
open flame to check for gas leaks.
NOTE: As a courtesy, many local gas utilities will inspect a gas appliance installation.
Check with your utility to see if this service is provided in your area.
NOTE: The minimum permissible gas (natural or mixed) supply pressure for purposes in
input adjustment is 4.5 inches of water.
GAS IGNITION
This dryer uses an automatic ignition system to light the main burner when the dryer is
turned on.
If a 4-wire receptacle of NEMA type is used, a matching UL Listed power supply cord (pig-
tail) must be used. This cord contains four No. 10 copper conductors with spade or ring
terminals on the dryer end. The 4th (grounding) conductor must be identified by a green
cover and the neutral conductor by a white cover. The cord should have a suitable strain
relief, and should be a minimum of 4 feet long. The power supply cord and strain relief are
not provided with the dryer.