G.F.I.
If the electric dryer is protected by a GROUND FAULT INTERRUPTER, follow the pro-
cedure for a 4-wire hookup below.
4-WIRE RECEPTACLE
The frame of a 120/240 Volt machine must NOT be connected to neutral terminals. It
MUST be connected to the 4th wire (green of the power supply) or to the metallic covering
of a three-wire supply.
If a 4-wire receptacle of NEMA type is used, a matching UL Listed power supply cord (pig-
tail) must be used. This cord contains four NO. 10 copper conductors with spade or ring
terminals on the dryer end. The 4th (grounding) conductor must be identified by a green
cover and the neutral conductor by a white cover. The cord should have a suitable strain
relief and should be a minimum of 4 feet long. The poser supply cord and strain relief are
not provided with the dryer.