6, ELECTRIC DRYER SECTION
To Make The Electrical Connection
Review the electrical requirements on the other pages of these instructions.
IMPORTANT - The dryer frame is grounded to the neutral conductor at the terminal block.
If the codes do not permit grounding through the neutral, refer to 4 WIRE SYSTEM CON-
NECTIONS.
Remove the terminal block cover plate.
Insert the power cord with a U.L. listed strain relief through the hole provided in the cabinet
near the terminal block. Note, a strain relief must be used.
3-WIRE SYSTEM CONNECTIONS
The neutral (white or center wire on power cord) conductor must always be connected to the
center (silver colored) post of the terminal block.
Secure the power cord to the terminal block. Do not loosen the nuts already installed. Be
sure they are tight. Use a 3/8" deep well socket.
If the power cord has terminals, place the terminals over the existing nuts on the posts.
Secure in place using the nuts provided in the accessories package. If the power cord does
not have terminals, use the cupped washers ahead of the nuts.
Connect the other two wires of the power cord to the outer posts of the terminal block using
the nuts provided in the accessory package.
Be sure the terminal block nuts are tight. Secure the power cord in position. Tighten the
strain relief screw(s) in order to clamp the strain relief to the cord.
Replace the terminal block cover.
BEFORE OPERATING OR TESTING, follow the grounding instructions on the other
pages of these instructions.