Specifications
6-5
TROUBLESHOOTING GUIDE
Some tests will require accessing components. See Figure 2 for component locations.
PROBLEM POSSIBLE CAUSE / TEST
NOTE: Possible Cause/Tests MUSTbe performedinthe sequence shown foreach problem.
WON’T POWER UP.
(No response when buttons are
pressed.)
1. Supply connections. See TEST #1.
2. Check harness connections.
3. Console electronicsand housing assembly.See TEST #5.
WON’T START CYCLE WHEN
START BUTTON IS PRESSED.
1. If number display flashes, check to be surethe door is completely
shut,and pressand hold down START forabout 1second.
2. See TEST #2.
3. See TEST #6.
WON’T SHUTOFF WHEN
EXPECTED.
1. Check PAUSE/CANCEL button. See TEST #5.
2. Console electronicsand housing assembly.See TEST #5.
3. Moisture sensor. See TEST #4.
CONTROL WON’T ACCEPT
SELECTIONS.
Console electronicsand housing assembly.See TEST#5.
WON’T HEAT.
1. Heater. See TEST #3.
2. Check harness connections.
3. Check installation.
HEATSINAIR CYCLE.
Heater. See TEST #3.
SHUTSOFF BEFORE CLOTHES
ARE DRY.
1. Checkthe dryness settingfor auto cycles.
2. Checkfor full lint screen.
3. Checkfor clogged vent.
4. Moisture sensor. See TEST #4.
5. Dryness adjust. See TEST #4a.
Moisture Sensor
Strips
Heater
Assembly
Door
Switch
See Accessing & Removing the
Electronic Assemblies to access:
See Removing the Back
Panel to access:
See Removing theToe Panel,
to access:
•
•
Drum Light Assembly
Blower Motor Assembly
•
•
•
•
•
•
Moisture Sensors
Exhaust Thermistor
Thermal Cut-off
High LimitThermostat
Heater Assembly (Electric or Gas)
Thermal Fuse
•
•
Machine Control Electronics
Console Electronics
and Housing
Figure 2. Component locations.
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
WARNING