Specifications

6-4
DISPLAY FAULT CODES
The fault codes below would be indicated when attempting to start a drying cycle, or after activating
the diagnostic test mode.
DISPLAY DESCRIPTION EXPLANATION AND RECOMMENDED PROCEDURE
PF
Power Failure
“PF” flashes to indicate that a power failure occurred while the dryer was
running. Press START to continue the cycle, or press PAUSE/CANCEL to
clear the display.
F-01
Primary Control Failure
“F-01” flashes when there is a primary control failure. Replace the machine
control electronics. See Accessing & Removing the Electronic Assemblies.
F-02
Keypad/User Interface
Failure
“F-02” flashes when there is a stuck button or user interface mismatch. This
fault code will ONLY appear when in the diagnostic test mode. See TEST #5.
F-22
Exhaust Thermistor Open
“F-22” flashes if the thermistor is open. See TEST #3a.
F-23
Exhaust Thermistor Shorted
“F-23” flashes if the thermistor has shorted. See TEST #3a.
F-26
Motor Drive System Failure
“F-26” flashes if there is a motor drive system failure. See TEST #2.
F-28
Moisture Sensor Open
“F-28” flashes if the moisture sensor strip is open. This fault code will ONLY
appear when in the diagnostic test mode. See TEST #4.
F-29
Moisture Sensor Shorted
“F-29” flashes if the moisture sensor strip has shorted. This fault code will
ONLY appear when in the diagnostic test mode. See TEST #4.
1M 2M 3M 5M 6M
=
Contacts closed
Contacts
Function
Start
Run
Red
Lt. Blue
Blue-White (Elec)
White (Gas)
Green-Yellow
Red
Black-White
BLACK
BLUE
BLUE
WHITE
WHITE
WHITE
Gas Valve - Gas Dryer
Pluggable Drive Motor Switch
Centrifugal Switch (Motor)
Gas Valve - Gas Dryer