Specifications
6-2
Diagnostic: Saved Fault Codes
If there are saved fault codes, the most recent
fault code will alternately show “F-” and “XX”
where XX is the fault code, and all the cycle
selectorindicatorsash.
Diagnostic: Active Fault Codes
Ifthereisanactivefaultcode,itwillbeashing
inthedisplay(thecycleindicatorsdonotash).
Review the Display Fault Codes table for the
recommended procedure.
If there is no active fault code, 88 will be
displayed.
Diagnostic: Console Buttons and Indica-
tors
Pressing buttons and rotating the cycle selector
will turn off the corresponding indicator and
sound a beep as shown in Figure 1, Console
Diagnostics. Pressing more time will toggle
the left digit on the display while sounding a
beep. Pressing less time will toggle the right
digit on the display while sounding a beep.
If indicators fail to come on and beep after
pressing buttons and rotating the cycle sel-
ector, go to TEST #5.
Press and release the
samebutton usedto
activate Diagnostics
g
g
g
g
g
g
g
beep tone
Second mostrecent fault codeis
displayed.
Repeat
beep tone
Third mostrecent fault codeis
displayed.
Repeat
beep tone
Fourth most recent fault code is
displayed.
Repeat
All indicators momentarily turnoff, then stay on.