Specifications

5-5
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
WARNING
DRIVE MOTOR
Refer to page 4-12 for the procedure for ac-
cessing the drive motor.
1. Unplug dryer or disconnect power.
2. Turn off gas supply to dryer.
3. Disconnect the plug from the motor con-
nector.
4. Set the ohmmeter to the R X 1 scale.
5. Touch one ohmmeter test lead to the blue
motor wire connector, and the other test
lead to connector pin 5 (white-orange
wire). The meter should indicate between
2.4 and 3.6 Ω (main winding).
6. Touch one ohmmeter test lead to the blue
motor wire connector, and the other test
lead to connector pin 3 (violet wire). The
meter should indicate between 2.4 and
3.8 Ω (start winding).
7. If either resistance is much larger than
4 Ω, replace the motor.
If the resistances at the motor are cor-
rect, check for a failed belt switch.
If the belt switch is okay, check for an
open circuit between the motor and the
machine control electronics assembly.
Pin 5 (WH-OR)
Pin 3 (VI)
Blue Motor Wire
Motor Connector
Drive Motor
Belt Switch