Specifications

4-16
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1. Unplug dryer or disconnect power.
2. Turn off gas supply to dryer.
3. Remove the toe panel from the dryer (see
page 4-8 for the procedure).
WARNING
REMOVING THE GAS BURNER ASSEMBLY COILS
4. Remove the ignitor from the burner (see
page 4-14 for the procedure).
5. Disconnect the 2-wire and 3-wire con-
nectors from the burner coil assembly
terminals (see the top right photo).
6. Remove the two screws from the burner
support bracket and remove the bracket
from the burner.
7. Remove the two screws from the front of
the burner bracket and remove the burn-
er assembly from the dryer.
8. Remove the two screws from the coil re-
taining bracket.
Gas Burner Assembly
2-Wire
3-Wire
Coils w/Connectors
Support Bracket
Screws
Burner Bracket
Screws
9. Lift the two coils off their cores and re-
move them.
Retaining Bracket Screws
Gas Burner Assembly
LIFT