Specifications
4-14
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1. Unplug dryer or disconnect power.
2. Turn off gas supply to dryer.
3. Remove the toe panel from the dryer (see
page 4-8 for the procedure).
WARNING
REMOVING THE IGNITOR, FLAME SENSOR, HIGH-LIMIT
THERMOSTAT, AND THERMAL CUTOFF
(GAS MODELS ONLY)
4. To remove the ignitor:
a) Disconnect the ignitor wire connector
from the main harness (see the top
right photo).
b) Remove the 5/16˝ hex-head ignitor
bracket screw from the burner venturi
and remove the ignitor and bracket.
Gas Burner Assembly
Ignitor Connector
Ignitor Bracket
Screw
c) Remove the 5/16˝ hex-head ignitor
screw and remove the ignitor from the
bracket.
Ignitor Screw