Specifications
4-2
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before
operating.
Failure to do so can result in death or
electrical shock.
1. Unplug dryer or disconnect power.
2. Turn off gas supply to dryer.
3. Remove the rear screws from the top
cover of the dryer.
4. Lift the rear of the cover, pull back, and
remove the cover from the dryer.
WARNING
REMOVING THE CONSOLE AND
THE CONSOLE ELECTRONICS ASSEMBLY
Top Cover Screws
5. To remove the console:
a) Release the locking tab, and discon-
nect the console electronics board
connector from the machine control
electronics at P5.
b) Press out and unhook the two locking
tabs on the back of the console from
the chassis slots. Pull the bottom of
the console out slightly, then pull and
unhook the top catches from the plas-
tic holder, and remove the console.
Machine Control
Electronics Assembly
Console Electronics
Assembly
Connector P5
Console Locking Tabs
(Rear View)
Pull Out & Unhook
Machine Control
Electronics