Specifications
2-4
Recessed or closet installation - Dryer on 
pedestal
A. Recessed area
B. Side view - closet or confined area
A
B
 1"
(2.5 cm)
 1"
(2.5 cm)
 27"
 (68.6 cm)
 1"
(2.5 cm)
 5
"**
(12.7 cm)
 28.65"
(72.77 cm)
15" min.*
(38.1 cm)
14" max.*
(35.6 cm)
Installation spacing for cabinet installation
The dimensions shown are for the recom-•
mended spacing.
For cabinet  installation, with a door, mini-•
mum ventilation openings in the top of the 
cabinet are required.
7"* (17.8 cm)
9"*
(22.9 cm)
7"* (17.8 cm)
5"**
 (12.7 cm)
28.65"
(72.77 cm)
27"
(68.6 cm)
 1"
(2.5 cm)
(2.5 cm)
 1"
(2.5 cm)
1"
* Required spacing
** For side or bottom venting, 0˝ (0 cm) spacing is allowed.
48 in.
2
 *
(310 cm
2
)
3"* (7.6 cm)
3"* (7.6 cm)
1"* (2.5 cm)
24 in.
2
 *
(155 cm
2
)
6"* (15.2 cm)
72"
(182.9 cm) 
27"
(68.6 cm)
 5"*
(12.7 cm)
 1"
(2.5 cm)
 1"
(2.5 cm)
* Required spacing
Recommended installation spacing for 
recessed or closet installation with 
stacked washer and dryer
The dimensions  shown are  for the  recom-
mended spacing.
* Required spacing
Mobile home - additional installation require-
ments
This dryer is suitable for mobile home instal-
lations. The  installation  must  conform  to  the 
Manufactured Home Construction and Safety 
Standard, Title  24  CFR,  Part  3280  (formerly 
the Federal Standard for Mobile Home Con-
struction and Safety, Title 24, HUD Part 280) 
or Standard CAN/CSA-Z240 MH.
Mobile home installations require:
Metal exhaust  system hardware, which  is •
available for purchase from your dealer.
Special  provisions  must  be  made  in  mo-•
bile homes to introduce outside air into the 
dryer. The opening (such as a nearby win-
dow) should be at least twice as large as 
the dryer exhaust opening.
* Required spacing
** For side or bottom venting, 0˝ (0 cm) spacing is allowed.