Installation guide
4
•Havebatteryback-uppower;
•Meet ANSI/UL 2034 Standards and comply with
NFPA 720 (2005 Edition); and Approved and listed
by a Nationally Recognized Testing Laboratory as
recognizedunder527CMR.
c.) A Product-approved vent terminal must be used,
andifapplicable,aproduct-approvedairintakemust
be used. Installation shall be in strict compliance
with the manufacturer’s instructions. A copy of the
installationinstructionsshallremainwiththeappliance
orequipmentatthecompletionoftheinstallation.
d.) Ametalorplasticidenticationplateshallbemounted
attheexteriorofthebuilding,fourfeetdirectlyabove
the location of vent terminal. The plate shall be of
sufcientsize,easilyreadfrom a distance ofeight
feetaway,andread“GasVentDirectlyBelow”.
2. For direct-vent appliances, mechanical-vent heating
appliancesordomestichotwaterequipmentwherethe
bottomoftheventterminalandtheairintakeisinstalled
abovefourfeetabovegradethefollowingrequirements
mustbesatised:
a.) A(CO)detectorandalarmshallbeplacedoneach
oorlevelwheretherearebedrooms.Thedetector
shallcomplywithNFPA720(2005Edition)andbe
mountedinthelivingareaoutsidethebedroom(s).
b.) The(CO)detectorshall:
•Belocatedintheroomthathousestheapplianceor
equipment;
•Behard-wiredorbatterypoweredorboth.
•ShallcomplywithNFPA720(2005Edition).
c.) A product-approved vent terminal must be used,
andifapplicable,aproduct-approvedairintakemust
be used. Installation shall be in strict compliance
with the manufacturer’s instructions. A copy of the
installationinstructionsshallremainwiththeappliance
orequipmentatthecompletionoftheinstallation.
GeneralInformation
Theinformationlistedbelowisforreferencepurposesonly
anddoesnotnecessarilyhavejurisdictionoverlocalorstate
codes.Alwaysconsultwithlocalauthoritiesbeforeinstalling
anygasappliance.
DuctSystems
• USandCANADA:AirConditioningContractorsAssociation
(ACCA) Manual D, Sheet Metal and Air Conditioning
Contractors National Association (SMACNA), or American
Society of Heating, Refrigeration, and Air Conditioning
Engineers(ASHRAE)FundamentalsHandbook
Electrical Connections
• US:NationalElectricalCode(NEC)ANSI/NFPA70
• CANADA:CanadianElectricalCodeCSAC22.1
Gas Piping & Gas Pipe Pressure Testing
• US:NFGCandNationalPlumbingCodes
• CANADA:NSCNGPIC
General Installation
• US: Current edition of the NFGC and the NFPA 90B. For
copies,contacttheNationalFireProtectionAssociationInc.,
Batterymarch Park, Quincy, MA 02269; or American Gas
Association,400N.Capitol,N.W.,WashingtonDC20001or
www.NFPA.org
• CANADA:NSCNGPIC.Foracopy,contactStandardSales,
CSA International, 178 Rexdale Boulevard, Etobicoke
(Toronto),Ontario,M9W1R3Canada
Safety
• US:(NFGC)NFPA54–1999/ANSIZ223.1andtheInstallation
Standards,WarmAirHeatingandAirConditioningSystems
ANSI/NFPA90B.
• CANADA:CAN/CSA-B149.1and.2–M00NationalStandard
ofCanada.(NSCNGPIC)
OperationofFurnaceDuringConstruction
CAUTION:
Operatinggasfurnacesinconstructionenvironments
cancauseavarietyofproblemswithinthefurnace
and may significantly reduce the life or the
performanceofthefurnace.Thereforeoperating
thefurnaceduringconstructionisnotpermitted
andwillvoidthewarranty.