Specifications

12
CONNECT VENT
Using a 102 mm (4") clamp, connect vent to exhaust outlet
in dryer. If connecting to existing vent, make sure vent is
clean. Dryer vent must t over dryer exhaust outlet and inside
exhaust hood. Check that vent is secured to exhaust hood
with a 102 mm (4") clamp.
Move dryer to nal location. Avoid crushing or kinking vent.
After dryer is in place, remove corner posts and cardboard
from under the dryer.
1. Connect vent to exhaust outlet
2. Move dryer to nal location
Connect vent to exhaust hood
2.
Vent must t over the exhaust hood. Secure vent to exhaust
hood with 102 mm (4") clamp. Run vent to dryer location
using straightest path possible. Avoid 90° turns. Use clamps
to seal all joints. Do not use duct tape, screws, or other
fastening devices that extend into interior of vent to secure
vent, because they can catch lint.
INSTALL VENT SYSTEM
305 mm
(
12" mín.
)
305 mm
(
12" mín.
)
Install exhaust hood
1.
Install exhaust hood and use caulking compound to seal
exterior wall opening around exhaust hood.
NOTE: Side and bottom exhaust installations have a 90° turn
inside the dryer. To determine maximum exhaust length, add
one 90° turn to the chart.
The maximum length using a 51 mm x 152 mm (2"x 6")
rectangular vent with 2 elbows and a 64 mm (2-1/2") exhaust
hood is 2,4 m (8ft).
For exhaust systems not covered by the Vent System Chart (such
as multiple unit hookups, plenums, and power-assist fans), see
Service Manual, Part 603197. (To purchase the Service Manual,
contact your local authorized service dealer.
Vent System Chart
Number of
90° turns
or elbows
Type
of vent
Box/louvered
hoods
Angled
hoods
1
4
3
2
0
Rigid metal
Rigid metal
Rigid metal
Rigid metal
Rigid metal
15,8 m (52 ft.)
13,4 m (44 ft.)
11,0 m (36 ft.)
8,2 m (27 ft.)
6,1 m (20 ft.)
13,4 m (44 ft.)
11,0 m (36 ft.)
18,5 m (28 ft.)
6,4 m (21 ft.)
4,3 m (14 ft.
The Vent System Chart provides venting requirements that
will help achieve best drying performance.