Service manual
Component Specifications 
CAUTION
!
To avoid electrical shock, personal injury, or death, disconnect power to unit and discharge capacitor before 
servicing, unless testing requires power. 
©2005 Maytag Services
  16026267 9
Illustration Component  Testing  Results 
Fan motor 
Disconnect wires from terminals. 
Measure continuity from: 
Terminal to terminal..........................
Approximately 49 Ω 
Heater fan motor 
Disconnect wires from terminals. 
Measure continuity from: 
Terminal to terminal..........................
Approximately 29.5 Ω 
Relay 2 
Disconnect wires from terminals. 
Measure resistance at terminals: 
Idle state...........................................
Microwave state ...............................
Infinite 
Continuity 
Relay 4 
Disconnect wires from terminals. 
Measure voltage at terminals: 
Idle state...........................................
Convection state...............................
Infinite 
Continuity 
COM
NC
NO
Oven lamp switch 
Disconnect wires from terminals. 
Measure continuity from: 
COM to NO.......................................
Open infinite, Closed continuity 
Thermal cutout 
Disconnect wires from terminals. 
Measure resistance across terminals...
Oven TCO 
This TCO will reset by itself: 
ACM1580....................................  
JMC9158 ....................................  
Continuity 
Open at 230°F and closed at 140°F 
Open at 302°F and closed at 140°F 
Thermistor 
Disconnect wires from terminals. 
At room temperature. (68°F − 86°F) 
Measure resistance across terminals. 
Terminal 1 − 3 .................................
Approximately 255 KΩ 
Sensor assembly 
Disconnect wires from terminals. 
Measure resistance across terminals. 
Terminal 1 − 3 .................................
Terminal 1 − 2 .................................
Terminal 2 − 3 .................................
Approximately 3 KΩ 
Approximately 6 KΩ 
Approximately 3 KΩ 
COM
NC
NO
Monitor interlock 
Disconnect wires from terminals. 
Measure resistance at following 
terminals: 
NC − COM........................................ 
NOTE: When line fuse is blown replace 
monitor, primary, and secondary 
interlock switches. 
Door open continuity, door closed 
infinite. 
COM
NC
NO
Primary interlock 
Disconnect wires from terminals. 
Measure resistance at following 
terminals: 
NO − COM........................................ 
NOTE: When line fuse is blown replace 
monitor, primary, and secondary 
interlock switches. 
Door open infinite, door closed 
continuity. 
COM
NC
NO
Secondary interlock 
Disconnect wires from terminals. 
Measure resistance at following 
terminals: 
NC − COM........................................ 
NOTE: When line fuse is blown replace 
monitor, primary, and secondary 
interlock switches. 
Door open continuity, door closed 
infinite. 