Installation Guide

Outdoor Ceiling Fixture Installation Instructions
1. Please read all warnings and instructions before installation.
2. The fixture must be wired in accordance with the National Electric
Code and applicable local codes or ordinances.
3. To insure personal safety, proper grounding is required.
WARNING:
1. To avoid fire, shock, or death, disconnect power at circuit breaker
or fuse before the installation.
2. If you are unsure about the installation or maintenance of the
Outdoor Ceiling Fixture, please consult a qualified electrician.
SAFETY:
INSTALLATION LOCATION:
This fixture must only be wall-mounted. Be certain that the receiving
junction box is well secured and can support the weight of the lamp.
1. This fixture should not be used in areas with limited ventilation or
high ambient temperature exceeding 45°C.
2. Fixture cannot be used with a dimmer switch, motion sensor and
other electronic switching devices.
INSTALLATION NOTES:
1. Make sure POWER is turned OFF at the circuit breaker box or remove fuse.
2. Carefully disconnect and remove the old light fixture if applicable.
3. Using the (Qty. 2) CROSSBAR SCREWS provided, mount the CROSSBAR
BRACKET into the JUNCTION BOX.
4. Locate and retrieve the supply wires from the JUNCTION BOX.
a. Connect the white wire from the fixture to the NEUTRAL wire in the
JUNCTION BOX (typically white).
b. Connect the black wire from the fixture to the HOT wire in the JUNCTION
BOX (typically black).
c. Connect the bare copper wire to the GROUND wire in the JUNCTION
BOX (typically bare). If the GROUND wire is not present in the JUNCTION
BOX, connect the bare copper wire to the green GROUND SCREW on the
CROSSBAR BRACKET which must be connected to GROUND for safety.
5. Adjust the UPPER CROSSBAR as necessary and securely tighten both
CROSSBAR SET SCREWS.
6. Insert the (Qty. 2) MACHINE SCREWS on the UPPER CROSSBAR through
the holes in the FIXTURE BASE PLATE and tighten by using the (Qty. 2)
SILVER CAP NUTS. Make sure that the fixture is tightly secured against the
ceiling. If the fixture is loosely mounted or if the SILVER CAP NUTS cannot
be tightened completely, it can be fixed as follows:
The (Qty. 2) MACHINE SCREWS on the UPPER CROSSBAR can be
adjusted by loosening their nuts (not seen in figures above) and then
screwing them in or out to alter the length of MACHINE SCREWS sticking
out from the UPPER CROSSBAR. Once the adjustment appears correct,
lock the MACHINE SCREWS in place with their nuts and then secure the
fixture tightly against the ceiling by using the (Qty. 2) SILVER CAP NUTS.
7. Once the FIXTURE BASE PLATE is secured, install the FIXTURE COVER
by using the (Qty. 2) BLACK CAP NUTS. If the fixture is not mounted tightly
up against the ceiling, readjust it as explained in Step 6.
8. Turn power ON at circuit breaker (or replace fuse) and confirm that the
fixture is functioning properly.
Figure 1
10" (254mm)
10" (254mm)
PRODUCT SPECIFICATION:
Part Number: MEL-9175NW
Input Voltage: 120 VAC
Amp Draw: 0.09 A
Frequency: 60 Hz
Rated Power: 12W
Suitable for: Damp Locations
THREE YEAR WARRANTY:
Maxxima extends a 3 year limited warranty to the original purchase
that the products listed are free from defects in material and/or
workmanship only. Maxxima will replace any warrantied product to
the original consumer/purchaser if the product fails because of
defects due to workmanship and/or materials within the limited
warranty period. Limited warranty is not transferable and applies to
the original installation of the Maxxima product. This offer does not
constitute in any way a product guarantee and Maxxima does not
hereby assume any obligation whatsoever beyond sending a free
replacement product.
PRODUCT DIMENSIONS:
Machine Screw
Ground Screw
Crossbar Set
Screws
Crossbar
Bracket
Upper Crossbar
Figure 2
INSTALLATION INSTRUCTION:
CAUTION: Read WARNING and SAFETY Notes before beginning
installation
Please refer to Figure 1 and Figure 2 while following installation instructions.
MEL-9175NW
www.maxximastyle.com
Junction Box
Crossbar Screw
Fixture Base
Plate
Bare Copper Wire
White Wire
Black Wire
Silver Cap Nut
Black Cap Nut
Fixture Cover
6"
(
152mm)
6" (152mm)