Installation Guide

15
Problem Possible Cause Probable Correcon
The body of the ice
maker is electried.
The grounding line isn't in the socket.
Use the socket that meets required
electrical standard.
The lines are creepage. Adjust, reconnect /replace lines
Scales occur
frequently inside
the machine.
The hardness of the water is too high.
Use a water-soening device installed in front of
the water inlet valve.
The ice cubes are
incomplete when
being dumped.
The sprinkler is blocked. Clean it; see "Interior Cleaning".
The sprinkler pressure of spray isn't enough.
Check.the water quality.
The water line may be blocked.
Noise during
operaon.
The feet are not leveled and locked
Level and lock the feet.
See “Leveling the Ice Maker.
Certain sounds are normal. See “Normal Sounds”.
The downcomer
doesn’t leak.
The water line blocks
Clean it, see user and care manual
"ice making system cleaning"
Harvesng ice is
dicult.
The water supply tap is turn o. Turn on the water supply tap.
The ambient temperature and water temperature
is too low
Adjust the temperature.
The ice maker stops
suddenly while
making ice.
The electricity is o. Reconnect the power supply line.
The room temperature is out of the stated range.
Cut o the electricity; let the ice maker stop
working ll the temperature returns within the
stated range.
The fuse is brown. Replace fuse.
The voltage of the power supply is low. Add manostat pump.
The venlaon louvers are covered. Remove the obstrucon.
Cubes are too big.
The ambient temperature and water temperature
is too low.
Adjust the temperature.
MIM75 MIM100 MIM130