Use and Care Manual
Service and Installation Manual 
6 
1.2 Function of LEDS 
2. MAIN FUNCTIONS  
2.1 HOW TO SEE THE SETPOINT 
1. Push and immediately release the SET key: the display will show the set point value; 
2. Push and immediately release the SET key or wait for 5 seconds to display the sensor value again. 
2.2 HOW TO CHANGE THE SETPOINT
1. Push the SET key for more than 2 seconds to change the set point value; 
2. The value of the set point will be displayed and the 
 LED starts blinking; 
3. To change the set value push the    or 
  key within 10 seconds; 
4. To memory the new set point value and push theSET key again or wait 10seconds. 
2.3 HOW TO START A MANUAL DEFROST 
Push the 
  key for more than 2 seconds and a manual defrost will start 
2.4 HOW TO LOCK THE KEYBOARD 
1. Keep pressed the   and 
    keys for more than 3seconds; 
2. The “POF” message will be displayed and the keyboard will be locked. At this point, it will be possible only 
to see the set point or the MAX or Min temperature stored; 
3. If a key is pressed more than 3s the ”POF” message will be displayed. 
2.5 HOW TO UNLOCK THE KEYBOARD 
Keep pressed the    and 
  keys together for more than 3seconds, until the “Pon” message is 
displayed, then press    or 
  key to select the item to check or program. 
3.ALARM SIGNALS  
HOW TO SEE THE ALARM AND 
RESET THE RECORDED ALARM 
1. Push the    or 
  key and the 
alarm signals will be displayed; 
2. When the signal is displayed, hold 
the SET key until the “rst” message 
is displayed, and push the SET key 
again, the “rst” message start 
blinking and the normal temperature 
will be displayed again. 