Use and Care Manual
Service and Installation Manual 
5 
OPERATION    
Do not throw items into the storage area. Failure to heed these recommendations could result in 
damage to the interior of the cabinet.
Refrigeration cycle 
Refrigerators:Every 6 hours, the unit will shut off to allow the evaporator coil to defrost and the controller will 
display the defrost symbol. When the coil temperature reaches 41°F or after 20 minutes, the unit returns to the 
refrigeration cycle.The factory setting for temperature range is 28° to 34°F.
Freezers: During the refrigeration cycle the controller supplies power to the condensing unit and evaporator fan 
motors. The evaporator fans will run at any time when the evaporator coil temperature is below 35°F andthey will 
cycle off during defrost period. Every 6 hours, the unit will shut off and the defrost heater will defrost the 
evaporator coil and the controller will display the defrost symbol. When the coil temperature reaches 45°F or 
after 20 minutes, the unit returns to the refrigeration cycle. 
1.  Anti-Condensation heaters on the door frames work in conjunction with the compressor. 
2.  The factory setting for temperature range is -7°F to -3°F. 
On/Off Switch: 
An on/off switch is located on the front of the bottom shroud. When the unit is on, the switch will glow green. 
Light Switch: 
A light switch is located next to on/off switch on the front of the bottom shroud.   
SOLID-STATE THERMOSTAT DESCRIPTIONS 
1. FRONT PANEL COMMANDS 
1.1 KEY FUNCTION 
To display target set point; in programming mode it selects a parameter or confirms an operation. 
To start a manual defrost 
To see the last temperature alarm; in programming mode it browses the parameter codes or 
increases the display value 
To see the last temperature alarm; in programming mode it browses the parameter codes or 
decreases the display value 
KEY COMBINATION 
To lock & unlock the keyboard 
To enter programming mode 
To return to the room temperature display 