Installation Guide
OPERATION
Do not throw items into the storage area. Failure to heed these 
recommendations could result in damage to the interior of the 
cabinet.
REFRIGERATION CYCLE
Refrigerators: Every 6 hours, the unit will shut off to allow the evaporator coil to defrost and the 
controller will display the defrost symbol. When the coil temperature reaches 41°F or after 20 
minutes, the unit returns to the refrigeration cycle. The factory setting for temperature range is 
28° to 34°F.
Freezers: During the refrigeration cycle the controller supplies power to the condensing unit 
and evaporator fan motors. The evaporator fans will run at any time when the evaporator coil 
temperature is below 35°F and they will cycle off during defrost period. Every 6 hours, the unit 
will shut off and the defrost heater will defrost the evaporator coil and the controller will display 
the defrost symbol. When the coil temperature reaches 45°F or after 20 minutes, the unit returns 
to the refrigeration cycle.
1. Anti-Condensation heaters on the door frames work in conjunction with the compressor.
2. The factory setting for temperature range is -7°F to -3°F.
On/Off Switch: 
An on/off switch is located on the front of the bottom shroud. When the unit is on, the switch 
will glow green.
Light Switch:
A light switch is located next to on/off switch on the front of the bottom shroud. 
SERVICE AND INSTALLATION MANUAL
www.maxximumfoodservice.com
4
CAUTION
DANGER
NOTE