Owners Manual

OPERATION
Do not throw items into the storage area. Failure to heed these
recommendations could result in damage to the interior of the
cabinet.
REFRIGERATION CYCLE
Freezers: During the refrigeration cycle the controller supplies power to the condensing unit
and evaporator fan motors. The evaporator fans will run at any time when the evaporator coil
temperatur
e is below 54°F and they will cycle off during defrost period. Every 6 hours, the unit
will shut off and the defrost heater will defrost the evaporator coil and the controller will display
the defrost symbol. When the coil temperature reaches 45°F or after 20 minutes, the unit returns
to the refrigeration cycle.
1. Anti-Condensation heaters on the door frames work in conjuncti
on with the compressor.
2. The factory setting for temperatu
re range is -7°F to -3°F.
Light Switch:
A light switch is located next to on/of
f switch on the front of the bottom shroud.
SERVICE AND INSTALLATION MANUAL
www.maxximumfoodservice.com
4
CAUTION
DANGER
TE