4.1 Connecting the electrical supply
All Maxx Air models require regular 3 prongs, ground with 120 volt power supply. Plug electrical cord into receptacle. If
using an extension cord be sure it is rated for at least 20 amps for the distance your cord is running. To be safe make sure
no other equipment, such as a radio or electrical equipment, is plugged into the same circuit. The Maxx Air should run
smoothly on 20 amp, 120 volt, and 60 Hz circuit.
4.2 Connecting the water supply
Connect standard water hose to female fitting on the right side of your Maxx Air (looking at the fan blade side). If your
water pressure is above 60 pounds per square inch (p.s.i.) you must use a pressure regulator (which can be found at your
local hardware store). Note: Do not connect to water source exceeding 60 p.s.i. this can cause damage to your Maxx Air.
5.0 Operating procedures
Back your Maxx Air unit up to a fresh air source such
as an open door or window so the unit can pull in
fresh air from the outside. Next, make sure you have
a natural exhaust at the opposite end of the room, bay
or building such as a window, door or bay door. This
will ensure maximum efficiency from your unit.
Finally make sure there are no obstructions between
your Maxx Air and the people / area you need to
cool.
5.1 Filling the units reservoir with water
Once your water hose is connected, turn water on and fill
the reservoir with water. Listen carefully. You can hear
water filling the reservoir. Check your water connection make sure there is no dripping. Once the reservoir is filled with
water the float valve will automatically shut off the water source. When you no longer hear the water running you know
that the float valve is fully operational (the water turns off automatically) and you are now ready to turn on the water pump.
Warning! Do not run water pump without water in the reservoir.
5.2 Turn-on pump
To turn-on the water pump - flip the toggle switch for the water pump to on. Switch is located on front side of unit.
Warning! Do not run water pump without water in the reservoir. The water pump will now begin pumping water to the
top of the unit so that gravity will allow the water to run down the backside of unit inside and on the cooling pads. Once
your Maxx Air cooling pads are saturated then, you are ready to turn fan on high and begin to feel the cooling effect from
your new Maxx Air. Note: After your cooling pads are broken in (typically takes 1 -2 weeks in operation) it will take less
time to saturate pads for start-up. This is a good time to dump the old water add ½ Evap-O-Matic Chemical Water
Treatment tablet and refill with fresh water. (Simply remove a cooling pad to place tablet inside of water reservoir).
NOTE: EXTENDED COOLING ZONE: 40’ TO 50’ FROM MAXX AIR
UNIT. AIR MOVEMENT INCLUDES WARM AIR MIXING WITH COOLED
AIR.