Thank you for choosing "ENERGY" gas boiler,a wall hung boiler of the latest generation with elegant style and advanced technology. L1PB series is a high-efficiency boiler for heating and domestic hot water production,running on natural gas, LPG or Artificial coal gas. Thanks to the microprocessor control and adjustment system with advanced self-diagnosis,unit operation is for the most part automatic.The power for heating is automatically governed by the control system.
Product Characteristics........................................................... 03 - 06 Technical Parameter..................................................................................... 04 Inside structure of gas boiler................................................................. 05 - 06 For Users' Manipulation.............................................................07-14 Safty and Caution Instruction........................................................................
Safety valve will open automatically to release pressure to protect the the boiler from damage Heating comfortably Adjusting the burning efficiency which makes the heating more comfortable. Apart from the radiator,Household air conditioning system and floor radiating heating system can match the boiler. when the water pressure reaches to 0.3 Mpa. Temperature extremes protection.The boiler will terminate the working program when overheated or a temperature sensor malfunction, occurs.
HEATING SYSTEM Model Gas type MGBWA070 MGBWA090 MGBWA0100 Natural gas, LPG, Artificial coal gas Rated input capacity (Btu/h) 70.000 90.000 100,00 Rated output capacity (Btu/h) 63.000 81.000 93.300 Min. input capacity for heating (Btu/h) 36.000 38.000 38.000 Min. output capacity for heating (Btu/h) 32.000 34.200 35.800 Min. input capacity for hot water (Btu/h) 33.000 33.500 33.500 Min. output capacity for hot water (Btu/h) 27.600 27.600 27.
DOMESTIC HOT WATER SYSTEM Model MGBWA070 MGBWA090 MGBWA0100 Max. working pressure (PSI) 100 100 100 Min. working pressure (PSI) 7,25 7,25 7,25 Hot water capacity with ∆ t=45 F (Lb/min) 23 30 35 Hot water temperature adjustment range ( ±3 Fº) (Fº) 86~140 86~140 86~140 Min.
1. Cold water inlet 2. Gas valve 3. Hot water temperature sensor 4. Water button 5. Burner 6. Electrode for ignition 7. Electrode for flame detection 8. Heat Exchanger 9. Distributor 10. Fan 11. Smoke sampling 12. Air sampling 13. Flow limited loop 14. Valve of air pressure difference 15. Heating water temperature sensor 16. Limited temperature sensor 17. Expansion tank 18. Automatic air venting valve 19. Pump 20. Safe valve 21. Automatic bypass-valve 22. Water venting valve G . Gas inlet U.
Inside Structure of Boiler Gas Boiler Inside Structure 15 15 1.Cold water inlet 14 16 14 16 2. Hot water temperature sensor 13 17 13 17 4. Heating water temperature sensor 12 3. Automatic bypass-valve 12 18 11 10 10 9 9 8 18 11 8 19 7 20 6 21 5 22 4 23 3 24 2 25 1 M U G E 19 7 20 6 21 5 22 4 23 3 24 2 25 1 R M U G E R 5. electromagnetism three way valve 6. Gas valve 7. Burner 8. Electrode for ignition 9. Electrode for flame detection 10.
I Water stored in the boiler cannot be used for drinking or cooking, Just for daily use. Gas type must be in conformity to type on the tag. Please use the AC 110V/60Hz with supplied plug.To keep safety, the boiler should have earth connection. Have the boiler serviced by a qualified authorized service technician. Please keep ventilation at times when the boiler works.
Before affusion, turn on the automatic air vent valve on the circulation pump and the air-vent valve at the end of the heating system. Fill softened water into the preset position for affusion on the pipe of heating system.Observe the pressure meter on the operation panel,stop filling in water when the pressure reaches between 0.1-.12Mpa(1—1.12 bar) Turn on the boiler (do not turn on the gas valve),then the pump start working.when the pressure drops to 1 bar, turn off the boiler.
You should keep all the parts of the boiler running Please follow the below instruction and the power supply on Sumer/winter Check button.When the water temperature is below 8 air-tightness when the gas valve is closed,then centigrade,the burner and pump will start until the open it, here should no gas through on the timer temperature rises to 30 centigrade.
1. Winter button 2. Summar button 3. DHW temperature up/down button 4. CH temperature up/down button 5. Reset button 6. Power on/off 7. Cold indication 8. Temperature display and malfunction code display 9. Over-heat problem display 10. Summar 11. Winter 12. Heating mode 13. Normal flame indication 14. DHW mode 15. Antifreezing 16. System water pressure indicator 17. Fan motor/fan pressure on/off malfunction 18. Ignition failure 19. Temperature sensor malfunction 20.
When turn the knob 5, the boiler doesn't ignite in CdUtion: Maintenance should be taken by 10 seconds, the red indicator 3 lights. technician. Check the gas valve is opened or not, press the Gas smell. The gas has leaked, so the pipe RESET knob to restart the boiler to ignite once should be checked if sealed. more, if the boiler still doesn't start up, turn off the When the fan is operationg, the flame can't cover boiler and ask for technician. the burner.
MGBWA100N11LA
The circulation pump head and flow should match the boiler system The whole system should be clean,with no sediment, rust, leakage, and drip-drop. While affusing and refilling water. a waterpurification must be equipped. Don't install the boiler to the place close to any combustible material. The wall on which the boiler is installed must be able to support a hang weight of 45KG,and if it's made of combustive materials,it should be covered with anti-combustive at least 3 mm thick.
For Installation Fix the hanging board for installation Adjust the hanging board with a gradienter Add washer if necessary. Mark the fixing points. Take off the hanging board and drill holes on the wall Fix the hanging board on the wall with screws Adjust it level with a gradienter MGBWA100N11LA Attention: The min. space should be allowed for the maintenance purpose, as shown on the right picture.
Before connecting gas pipes, please check: Whether the type of gas supplied matches that specified on the name plate of boiler. Any other types of gas not specified on the name plate shall not be used. Whether the gas pipes are clean. Please install a gas filter if there are solid particles in gas. Please check the tightness of all connections after installation. Do not use the gas pipe as the earth wire. There must be a pipe, which connects outlet of safety valve to the ground.
The whole length of flue gas pipe is decided by the the distance between the boiler mouted place and the position outlet of flue gas pipe. The distance also decide whether the flow limited loop shall be removed and whether the extended pipes shall be used.
Hot water system is to meet the demand of domestic hot water,say the bath.It's composed of boiler,pipe,sanitary equipment(The following systems are for reference) Generally,there are two systems based on the different equipments and theory:Without water tank simple system and with water tank system. without water tank system The system is composed of boiler,sanitary hot water equipment and pipe.The boiler is connected with sanitary equipment by pipe.As the picture 3.
The water tank is equipped with a temperature sensor,which can watch the temperature inside of the tank.When the temperature is below the set temperature,the sensor send the information to the pump which begins to work,then the water in the tube flows,so the heating function of the boiler starts,When the temperature in the tank reaches the set temperature,the termperature sensor give the signal to the pump,which will stop working.