Product Manual

OPERATE THE ENGINE REGULARLY
The generator should be operated regularly to maintain the condition of internal parts. At least
every four weeks, start the engine and let it run for 10 to 15 minutes with a small load plugged
in such as a lamp or fan.
Monthly operation of the generator will dry out any moisture that has accumulated in the
windings which if left, can cause corrosion. It will also ensure that the unit is operating properly
should it be needed in an emergency.
PERFORM REGULAR MAINTENANCE
Perform periodic maintenance as directed in this manual to keep the generator in safe working
condition.
PREPARE ENGINE FOR LONG TERM STORAGE
If you will not be able to operate the generator regularly, you must prepare the engine for long
term storage to prevent gum deposits from forming and causing malfunction of the engine.
Prepare the generator for long term storage by removing all fuel from the tank and carburettor
OR adding fuel stabiliser to the petrol (following manufacturers instructions).
Fuel stabiliser steps:
1. Ensure tank is full
2. Add fuel stabiliser to fuel tank
3. Run engine at least 10 minutes after adding stabiliser to allow it to enter the fuel
system.
4. Shut off engine.
5. Disconnect spark plug wire and remove spark plug.
6. Add one teaspoon oil through spark plug opening.
7. Place rag over spark plug hole and turn starter (or pull the recoil) a few times to
lubricate the combustion chamber. This will distribute the oil and protect the cylinder
wall from corrosion during storage.
8. Replace spark plug, but do not reconnect the spark plug wire.
REMOVAL FROM STORAGE
Follow the normal procedures for pre-operation checks and starting. Use only fresh fuel to
refill the tank, if necessary, rather then re-using the old fuel.
A battery may lose some charge when not in use for prolonged periods of time. If the battery is
unable to crank the engine, plug in the 12V charger supplied. See Charging a Battery section for
more details.
If oil was inserted into the cylinder prior to storage, the exhaust may smoke for a short while
after starting the generator. This is normal and will cease within a minute or so of running
time.
28