Product Manual
ROTARENEG EHT GNIPPOTS
Stop the engine using the following steps:
1. Turn off all appliances. Disconnect all loads to the generator. Never start or stop the
generator with electrical devices plugged in or turned on.
2. Allow the generator to idle for 2-3 minutes and cool down.
3. Turn the engine switch to the OFF posi n. DO not leave the generator un it has
completely stopped.
4. Turn the RCBO switch to OFF posi on.
5. Turn the fuel valve to OFF posi
n.
A en on:
Ensure the generator is in a well-ven ted area as the unit will remain hot even a er switching
it off.
During an emergency:
If there is an emergency and the generator must be stopped quickly, push the engine control
switch to the OFF posi
on immediately.
PU DLIUB NOBRAC
Running the generator at low loads for extended periods can lead to carbon build-up on the
spark plug which may subsequently require cleaning. Carbon build-up can be a problem on
generators as the loading on the motor can vary considerably. If the generator has been used
for less than 50% of rate load, there is a chance of carbon build-up developing. Carbon build up
in the motor can be reduced by opera
ng the generator at approximately 75% of rated load for
25% of the
e the generator is used.
For instance, if the generator is used for 4 hours on low wa
age, run the generator for 1 hour
at around 75% of ra
ng. If the generator is being used for solely charging a ba
ery, its
recommended to run the 240V at around 500W for the generators up to 2000W if the charging
cycle will be run for many hours. When charging is complete, try and run the generator at
around 75% of rate load for an hour or so. Unleaded fuel without ethanol generally gives the
best results.