6. STORAGE:
Long term storage of your generator will require some
preventative procedures to guard against deterioration.
1. Be sure all appliances are disconnected from the
generator.
2. Add a properly formulated fuel stabilizer to the tank
(2-3 times manufacturer’s recommended amount).
3. Run the generator for 10 minutes so the treated fuel
cycles through the fuel system and carburetor.
4. With the generator running, turn the fuel valve to the
“OFF” position and let the generator run until fuel
starvation has stopped the engine. This usually takes
a few minutes.
5. Turn engine switch to the “OFF” position.
6. Allow generator to cool completely before continuing.
7. Optional: to ensure fuel is completely drained from
the carburetor, use the drain bolt on the carburetor
to empty any excess gasoline into an appropriate
container.
8. Remove the spark plug cap and spark plug and pour
about a tablespoon of oil into the cylinder.
9. Pull the recoil slowly to crank the engine to
distribute the oil and lubricate the cylinder.