Product Manual

32
Use the following formula to convert voltage and amperage to
watts: Volts x Amps = Watts
To prolong the life of your generator and attached devices,
follow these steps to add electrical load:
1. Start the generator without any electrical load
attached.
2. Allow the generator to run for several minutes to
stabilise.
3. Plug in and turn on the first item. It is advised to
attached the item that requires the largest load first.
4. Allow the generator to stabilise.
5. Plug in and turn on the next item.
6. Allow the generator to stabilise.
7. Repeat 5 and 6 for each additional item.
CONNECTING ELECTRICAL LOADS
1. Let the engine stabilize and warm up for a few minutes
after starting.
2. Prior to powering tools and equipment, make sure the
generators rate voltage and amperage capacity (120V
AC @ 7 AMPs, 12V DC @ 8 AMPs) is adequate to supply
all electrical loads that the unit will power. If powering