Technical data
Product Specifications
4-6 DiamondMax 10 80/100/120/160/200/250/300GB Serial ATA
4.8 Environmental Limits
Notes:
1. Margin Demonstrated implies the product will operate at the stated conditions
with an acceptable impact to the ARR specification for any OEM requiring
those values in their purchase specification.
2. The testing performed by Maxtor is consistent with ISO 7779. Variation in
acoustic levels from the idle specification may occur due to offline activity
according to the SMART specification and/or atmospheric conditions.
PARAMETER OPERATING
NON-OPERATING/
STORAGE
Temperature 0×C - 60×C
The drive temperature is
measured at the base plate
motor well.
low temperature (-40° C)
high temperature (71° C) per
MIL-STD-810E, method 501.3,
climatic category; hot-induced
conditions.
Thermal Gradient 25°C per hour (maximum)
Relative Humidity 5% to 95% (non-condensing)
Wet Bulb 37.7°C (maximum)
Altitude (relative to sea
level)
-650 to 10,000 feet -650 to 40,000 feet
Acoustic Noise
2
IDLE MODE
Bels
NORMAL
SEEK MODE
Bels
QUIET SEEK
MODE
Bels
Fluid
Bearing
Avg Avg Avg
1 Disk 2.5 3.2 2.6
2 Disk 2.6 3.8 2.7
3 Disk 2.9 3.8 3.0