Specifications

Chapter #14 - Appendix - Disk Array Error Codes 289 000001628
MaxAttach NAS 6000 Administration Guide
Chapter #14 - Appendix - Disk Array Error Codes
Mylex Error Codes Table
11/07/01 -- Revision 2.0.03A
401 401 4 Information BBU reconditioning is finished.
402 402 4 Information BBU reconditioning is canceled.
403 403 1 Serious Installation aborted.
404 404 1 Serious Controller firmware mismatch.
405 405 3 Warning BBU removed.
406 406 1 Serious WARM BOOT failed.
411 411 3 Warning Controller entered Conservative Cache Mode.
412 412 3 Warning Controller entered Normal Cache Mode.
413 413 3 Warning Controller Device Start Complete.
414 414 3 Warning Soft ECC error Corrected.
415 415 3 Warning Hard ECC error Corrected.
416 416 1 Serious BBU Recondition Needed.
417 417 3 Warning Controllers Partner Has Been Removed.
418 418 2 Error BBU out of service.
419 419 3 Warning Updated partners status.
420 420 3 Warning Relinquished partner.
421 421 3 Warning Inserted Partner.
422 422 3 Warning Dual Controllers Enabled.
423 423 3 Warning Killed Partner.
424 424 3 Warning Dual Controllers entered Nexus.
425 425 1 Serious Controller Boot ROM Image needs to be reloaded.
426 426 0 Critical Controller is using default non-unique world-wide name.
512 512 4 Information System started.-
513 513 4 Information Size table full.-
514 514 4 Information User logged in.-
515 515 4 Information User logged out.-
Table #1 - Mylex Error Codes (Sheet 7 of 8)
Gam_ev
ent
Number
User_ev
ent
Number
Priority
Number
Severity
Level
Description