11/07/01 -- Revision 2.0.03A
138 138 4 Information A rebuild has started on logical drive.
139 139 4 Information Rebuild on logical drive is over.
140 140 4 Information Rebuild on logical drive is cancelled.
141 141 2 Error Rebuild stopped with error.
142 142 2 Error Rebuild stopped with error. New device failed.
143 143 2 Error Rebuild stopped because logical drive failed.
144 144 4 Information Logical drive initialization started.
145 145 4 Information Logical drive initialization done.
146 146 4 Information Logical drive initialization cancelled.
147 147 2 Error Logical drive initialization failed.
148 148 4 Information A logical drive has been found.
149 149 4 Information A logical drive has been deleted.
150 150 4 Information Expand Capacity Started.
151 151 4 Information Expand Capacity Completed.
152 152 2 Error Expand Capacity stopped with error.
153 153 4 Information Bad Blocks found.
154 154 4 Information System drive size changed.
155 155 4 Information System drive type changed.
156 156 1 Serious Bad data blocks found. Possible data loss.
157 157 3 Warning System drive LUN mapping has been written to config.
158 158 1 Serious Attempt to read data from block that is marked in Bad Data Table
159 159 2 Error Data for Disk Block has been lost due to Logical Drive problem
160 160 2 Error Temporary-Offline RAID5/RAID3 array is available to the user again with the
possibility of data loss in the array.
161 161 2 Error Temporary-Offline RAID0+1/RAID1/RAID0/JBOD array is available to the user
again.
162 162 4 Information An standby rebuild has started on logical drive.
Table #1 - Mylex Error Codes (Sheet 4 of 8)
Gam_ev
ent
Number
User_ev
ent
Number
Priority
Number
Severity
Level
Description