Specifications
Chapter #14 - Appendix - Disk Array Error Codes 284 000001628
MaxAttach NAS 6000 Administration Guide
Chapter #14 - Appendix - Disk Array Error Codes
Mylex Error Codes Table
11/07/01 -- Revision 2.0.03A
21 21 4 Information SCSI command retried on hard disk.
22 22 3 Warning Parity error found.
23 23 3 Warning Soft error found.
24 24 3 Warning Misc error found.
25 25 4 Information SCSI device reset.
26 26 4 Information Active spare found.-
27 27 4 Information Warm spare found.-
28 28 4 Information Request Sense Data available.
29 29 4 Information Initialization started.
30 30 4 Information Initialization completed.
31 31 3 Warning Initialization failed.
32 32 4 Information Initialization canceled.
33 33 1 Serious A hard disk failed because write recovery failed.
34 34 1 Serious A hard disk failed because SCSI bus reset failed.
35 35 1 Serious A hard disk failed because double check condition occurred.
36 36 1 Serious A hard disk failed because device is missing.
37 37 1 Serious A hard disk failed because of gross error on SCSI processor.
38 38 1 Serious A hard disk failed because of bad tag from the device.
39 39 1 Serious A hard disk failed because command to the device timed out.
40 40 1 Serious A hard disk failed because of the system reset.
41 41 1 Serious A hard disk failed because of busy status or parity error.
42 42 1 Serious A hard disk set to failed state by host.
43 43 1 Serious A hard disk failed because access to the device met with a selection time out.
44 44 1 Serious A hard disk failed because of a sequence error in the SCSI bus phase handling.
45 45 1 Serious A hard disk failed because device returned an unknown status.
46 46 1 Serious A hard disk failed because device is not ready.
Table #1 - Mylex Error Codes (Sheet 2 of 8)
Gam_ev
ent
Number
User_ev
ent
Number
Priority
Number
Severity
Level
Description