The Mylex RAID Controller Error Codes are used to generate the error messages related
to the RAID Controller and its attached disk drives.
Mylex Error Codes Table
Table #1 - Mylex Error Codes (Sheet 1 of 8)
Gam_ev
ent
Number
User_ev
ent
Number
Priority
Number
Severity
Level
Description
1 1 4 Information A hard disk has been placed online.
2 2 4 Information A hard disk added as hot spare.
3 3 3 Warning Hard disk error found.
4 4 3 Warning Hard disk PFA condition found, this disk may fail soon.
5 5 4 Information An automatic rebuild has started.
6 6 4 Information A rebuild has started.
7 7 4 Information Rebuild is over.
8 8 4 Information Rebuild is cancelled.
9 9 2 Error Rebuild stopped with error.
10 10 2 Error Rebuild stopped with error. New device failed.
11 11 2 Error Rebuild stopped because logical drive failed.
12 12 1 Serious A hard disk has failed.
13 13 4 Information A new hard disk has been found.
14 14 4 Information A hard disk has been removed.
15 15 4 Information A previously configured disk is now available.
16 16 4 Information Expand Capacity Started.
17 17 4 Information Expand Capacity Completed.
18 18 2 Error Expand Capacity Stopped with error.
19 19 4 Information SCSI command timeout on hard device.
20 20 4 Information SCSI command abort on hard disk.