Specifications
Chapter #4 - Overview - NAS 6000 Disk Array 122 000001628
MaxAttach NAS 6000 Administration Guide
Chapter #4 - Overview - NAS 6000 Disk Array
RAID Array Organization
11/07/01 -- Revision 2.0.03A
RAID Array Organization
The system logical drives are default configured as Redundant Arrays of Independent Disks
(RAID). the RAID methodology and technique used varies with the function of the
logical drive. The RAID techniques used in each logical drive are:
Base Unit Drive C:\ - System O/S:
n Factory configured
n A first RAID 1 striped across a partition on three drives with a second RAID 1 striped
across another partition on three different drives.
n The two RAID 1 arrays above are combined into a RAID 0 mirrored array.
n This array cannot be changed without damaging the O/S image.
1-13 Hard Disk Drive Second Expansion Unit, Drive 3
1-14 Hard Disk Drive Second Expansion Unit, Drive 2
1-15 Hard Disk Drive Second Expansion Unit, Drive 1
2-0 Hard Disk Drive Base Unit, Drive 12
2-1 Hard Disk Drive Base Unit, Drive 11
2-2 Hard Disk Drive Base Unit, Drive 10
2-3 Hard Disk Drive Base Unit, Drive 9
2-4 to 2-6 Not Used
2-7 SCSI Controller Card - Channel 2 Mylex SCSI RAID Controller is located in the Base Unit card cage. ID 2-7
controls all devices on Bus 2.
2-8 to 2-15 Not Used
3-0 to 3-3 Not Used
3-4 Channel-3 SCSI Bridge Board Base and Expansion Units. ID shared by all Channel 3 Bridge Boards.
One Channel 3 Bridge board is located on each Expansion Unit. There is
no Channel 3 Bridge board in the Base Unit.
3-5 & 3-6 Not Used
3-7 SCSI Controller Card - Channel 3 Base Unit - Mylex SCSI RAID Controller is located in the Base Unit card
cage. ID 3-7 controls all devices on Bus 3.
3-8 Hard Disk Drive First Expansion Unit, Drive 12
3-9 Hard Disk Drive First Expansion Unit, Drive 11
3-10 Hard Disk Drive First Expansion Unit, Drive 10
3-11 Hard Disk Drive First Expansion Unit, Drive 9
3-12 Hard Disk Drive Second Expansion Unit, Drive 12
3-13 Hard Disk Drive Second Expansion Unit, Drive 11
3-14 Hard Disk Drive Second Expansion Unit, Drive 10
3-15 Hard Disk Drive Second Expansion Unit, Drive 9
Table #2 - Disk Array Components by SCSI Bus & ID Number (Sheet 2 of 2)
SCSI
Bus:ID
Component Name
Component Location - Drive Number from
Left