Product manual
Table Of Contents
- Chapter - Table of Contents
- Chapter - List of Figures
- Chapter - Chapter 1 INTRODUCTION
- Chapter - Chapter 2 PRODUCT DESCRIPTION
- Figure Caption - Figure 2-1 PCBA Jumper Location and Configuration
- Chapter - Chapter 3 PRODUCT SPECIFICATIONS
- Figure Caption - Figure 3-1 Outline and Mounting Dimensions
- Chapter - Chapter 4 HANDLING AND INSTALLATION
- Figure Caption - Figure 4-1 Single Pack Shipping Container
- Figure Caption - Figure 4-2 20-Pack Shipping Container
- Chapter - Chapter 5 ATA BUS INTERFACE AND ATA COMMANDS
- Chapter - Chapter 6 SERVICE AND SUPPORT
- Chapter - Appendix A BREAKING THE 137 GIGABYTE STORAGE BARRIER

Product Specifications
Maxtor DiamondMax16 60/80/120/160GB 3-5
3.5 Power Requirements
3.6 Power Mode Definitions
Spin-up
The drive is spinning up following initial application of power and has not yet
reached full speed.
Seek
A random access operation by the drive.
Read/Write
Data is being read from or written to the drive.
Idle
The drive is spinning, the actuator is parked and powered off and all other circuitry
is powered on.
The drive is capable of responding to read commands within 40 ms.
Standby
The motor is not spinning. The drive will leave this mode upon receipt of a
command that requires disk access. The time-out value for this mode is
programmable. The buffer is active to accept write data.
Sleep
This is the lowest power state – with the interface set to inactive. A software or
hardware reset is required to return the drive to the Standby state.
3.7 EPA Energy Star Compliance
Maxtor Corporation supports the goals of the U.S. Environmental Protection
Agency’s Energy Star program to reduce the electrical power consumption of
computer equipment.
MODE 12V (MA) 5V (MA) POWER (W)
Spin-up (peak) 1779 715 24.9
Seek 587 628 10.2
Read/Write 280 591 6.3
Idle 224 582 5.7
Standby 41 116 1.1
Sleep 41 115 1.1